The AirTAC GFR200C06LF3T AirTAC Filter Regulator NPT1/8 Low Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06LF3T is an AirTAC GFR-series filter regulator: one body that removes water and particulate from compressed air and then regulates pressure for the circuit downstream. This 200-size unit is built for 1/8 in NPT ports and is the low-pressure (L) type, intended for circuits that hold a reduced, stable setting rather than full line pressure. It carries the standard 40 um filter element, a differential-pressure drain, an embedded square gauge reading in bar, and a metal bowl. A mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR family spans 200, 300, 400 and 600 sizes with ports from 1/8 in to 1 in, and options including a 5 um (W) filter element, automatic or manual drains, PT or G threads, alternative gauge scales and bracket variants. Flow for this series is published as curves rather than a single rating, so ask us to confirm sizing and datasheet figures for your application before ordering.
| Model | GFR200C06LF3T AirTAC Filter Regulator NPT1/8 Low Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding paint spray guns on a finishing line, where the low-pressure regulator holds a gentle, stable gun supply while the 40 um element keeps water and pipe scale out of the finish.
Regulating hold-down cylinders and air tables on carton-sealing or labelling machinery that runs its pneumatic function below full line pressure.
Supplying bench air tables and pneumatic fixtures in electronics assembly, where a low regulated setting and filtered air protect delicate workpieces.
Size the unit by port and demand: this configuration is 200 frame with 1/8 in NPT threads; if your line runs larger ports or higher demand, step up through the 300, 400 and 600 frames. Because this is the low-pressure (L) type, it is meant for reduced downstream settings - the exact adjustment range is not published in our data, so confirm it with us against your setpoint. The drain is differential-pressure as coded, with automatic (A) and manual (M) versions orderable in the same frame. The element is the standard 40 um grade; a 5 um (W) element is available where finer filtration is needed. The gauge is the embedded square type reading in bar, with psi and MPa scales and an external round gauge as alternatives. Thread here is NPT (T); PT is the standard thread and G (BSPP) is also a catalogue option. A mounting bracket is included. Flow is published as curves, not a single rating - ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes G-series flow as curves rather than a single rated figure, so we do not quote a number here. Send us your line pressure, downstream setting and air demand, and we will confirm the sizing from the datasheet on request.
This unit is coded with the differential-pressure drain, which discharges collected condensate based on the pressure difference across the filter element. If your application suits a different approach, automatic (A) and manual (M) drain versions are available to order in the same frame.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.