The AirTAC GFR200C06LJC1T AirTAC Filter Regulator NPT1/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C06LJC1T is an AirTAC GFR-series filter regulator: water and particulate filtration plus pressure regulation combined in a single body with a drain bowl underneath. This configuration is built for 1/8 in NPT ports, uses the standard 40 um filter element, expels condensate by differential pressure, and carries a round pressure gauge with an MPa scale. The L in the code marks the low-pressure regulator type, intended for circuits that need reduced setting pressures, and the unit is ordered without a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 up to 1 in, and can be ordered with a 5 um element (code W), automatic or manual draining, square or round gauges scaled in MPa, psi or bar, a reverse/check valve, and PT, G or NPT threads. Flow for this series is published as curves rather than a single rating, so ask us to confirm the datasheet and sizing for your application.
| Model | GFR200C06LJC1T AirTAC Filter Regulator NPT1/8 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Holding a reduced, steady supply pressure to air-fed spray guns and coating lines in a finishing booth, with the 40 um element keeping water and debris out of the fluid tip.
Filtering and regulating compressed air to bench-top analysers, sample pumps and small test rigs fed from a shop-air drop, with the local MPa gauge for repeatable settings.
Conditioning air to small pneumatic cylinders and actuators on packaging and assembly machinery, protecting seals from condensate while holding a low set pressure.
Choose the size by port and flow: this 200-series unit sits at the small end, stepping up through 300, 400 and 600 as port size and air demand grow. Drain choice matters: differential-pressure draining (this unit) passes condensate automatically under flow, while automatic (A) and manual (M) drains suit unattended or rarely visited installations. The 40 um element is standard; specify W for the 5 um grade where finer protection is needed. Gauges can be embedded square or external round, scaled in MPa, psi or bar, and threads come as PT (standard), G or NPT. Because flow is published as curves rather than a single rated figure, send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes GFR flow as performance curves rather than a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow and sizing from the datasheet before you order.
This unit drains condensate by differential pressure: as air flows through the element, the pressure difference opens the drain and collected water is expelled. If you prefer, GFR units can be ordered with an automatic drain (code A) or a manual drain (code M) instead.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.