The AirTAC GFR200C06MF2WK AirTAC Filter Regulator PT1/8, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06MF2WK is a filter regulator: filtration and pressure regulation combined in one body, with a drain bowl but no lubricator. This size-200 unit takes a PT1/8 thread, carries the 5 um filter element (code W), drains by hand through the manual drain, and is fitted with an embedded square gauge scaled in psi and a reverse/check valve (code K); the mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi), the working temperature range is -5 to 70 C (non-freezing), and the standard-type regulator adjusts from 0.05-0.9 MPa (7-130 psi).
This is a genuine AirTAC part. Across the GFR family you can move between sizes 200, 300, 400 and 600, ports from 1/8 in to 1 in, 40 um or 5 um filtration, differential-pressure, automatic or manual drains, and gauge or no-gauge builds. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application before ordering.
| Model | GFR200C06MF2WK AirTAC Filter Regulator PT1/8, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Feeding solenoid valve manifolds on a carton-sealing or filling line: the 5 um element keeps debris and carried-over water out of the valves while the regulator holds a steady signal pressure to the actuators.
Point-of-use air preparation for paint spray guns in a finishing booth: clean, regulated air delivered at the gun, with the manual drain letting the operator bleed off collected water at the start of each shift.
Regulated supply to pneumatic clamps and tool-change cylinders on a machining cell, where the fitted reverse/check valve (code K) blocks backflow from the clamping circuit toward the supply side.
Size and port set the air capacity: step up from the 200 to sizes 300, 400 or 600 for larger ports (1/8 in up to 1 in) and more flow. Choose the drain to match the installation: manual, as on this unit (which also widens the regulating range to 0.05-0.9 MPa / 7-130 psi), automatic for unattended draining, or the differential-pressure default. Pick 40 um for general-purpose air or 5 um (code W) for finer protection of downstream equipment; select the gauge scale (MPa, psi or bar) and the thread (PT is the standard, with G and NPT available as order options). Because flow is published as curves rather than one rated figure, send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number here. Tell us your application, port size and operating pressure, and we will confirm the flow from the datasheet on request before you order.
The manual drain (code M) means an operator opens the drain to expel collected water, which suits attended points of use. It also widens the regulating range to 0.05-0.9 MPa (7-130 psi), compared with 0.15-0.9 MPa (20-130 psi) on the automatic and differential-pressure drain versions.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.