The AirTAC GFR200C06MLF2K AirTAC Filter Regulator PT1/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C06MLF2K is a compact filter regulator that removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is the 200 size with a PT1/8 port, the low-pressure regulator type for circuits that run at reduced setpoints, a manual drain bowl, the standard 40 um filter element, a square pressure gauge reading in psi, a built-in reverse/check valve, and a mounting bracket included. Maximum inlet pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part from the GFR200 series, the smallest step in the GFR range that runs up through 600 size with larger ports and higher flow capacity. Thread options PT, G (BSPP) and NPT are catalogue choices, and other drain, filter-grade and gauge configurations are available in the same family. Flow for this unit is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for your application on request.
| Model | GFR200C06MLF2K AirTAC Filter Regulator PT1/8 Low-Pressure |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
On a carton-sealing or case-packing line, low-pressure cylinders and clamps need clean air held at a reduced, stable setpoint. This filter regulator conditions the supply and lets an operator drain accumulated water from the bowl during shift checks, with the psi gauge giving a direct local reading.
In a paint or coating booth, the spray gun circuit depends on clean, dry air regulated to a low working pressure for consistent finish control. This unit filters particulate and moisture from the shop-air line, regulates the setpoint for the gun circuit, and its check valve holds the setting against backflow.
Pneumatically piloted valves and actuators on a process skid often need a dedicated filtered supply regulated to a low setpoint. Mounted on its included bracket close to the valve manifold, this unit conditions the pilot air, shows the setpoint on the psi gauge, and is drained manually during routine rounds.
Start with the port step: the 200 size here carries a PT1/8 port, and stepping up to GFR300/400/600 gives larger ports for higher air demand - match the size to the flow your circuit needs. This unit is the low-pressure regulator type, chosen where the downstream setpoint sits below what a standard regulator targets; if you need a conventional range, the standard GFR version is the alternative. The manual drain means an operator opens the bowl drain during checks rather than relying on automatic or differential-pressure action. The standard element is 40 um; a 5 um element (code W) is available where finer filtration is wanted. The fitted square gauge reads in psi, with MPa or bar scales selectable by gauge code, and an external round gauge is an option. Thread is PT as standard with G and NPT as order options, and the bracket is included. Because flow is published as curves and not a single rating, send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as performance curves rather than a single rated figure, so we do not quote one number here. Tell us your application - supply pressure, downstream demand and allowable pressure drop - and we will confirm the relevant curve and datasheet figures for this exact model on request before you order.
The code carries the L position, making this the low-pressure regulator type, intended for circuits whose setpoint sits below the standard GFR regulator range; the exact adjustment range for the low-pressure type is not published, so we confirm it on request. The M in the code is the manual drain: water collected in the bowl is released by opening the drain fitting during maintenance, instead of an automatic or differential-pressure drain doing it for you.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.