The AirTAC GFR200C08JC3WT AirTAC Filter Regulator NPT1/4, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C08JC3WT is a size 200 filter regulator: it removes water and particulate from compressed air and sets downstream pressure in a single body. This configuration carries a 1/4 in NPT port, a 5 um filter element (the finer of the two catalogue grades), a differential-pressure drain that bleeds collected condensate automatically as flow passes through, and a round pressure gauge reading in bar. The regulator is the standard type with a 0.15-0.9 MPa (20-130 psi) adjustment range, and no mounting bracket is fitted, so plan your panel or manifold fixing accordingly.
This is a genuine AirTAC part from the GFR series, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drains, 40 um or 5 um filtration, gauge styles and scales, and PT, G or NPT threads. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet and sizing figures for your application before ordering.
| Model | GFR200C08JC3WT AirTAC Filter Regulator NPT1/4, 5 um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Cleaned and pressure-set air feeding the directional control valves that drive carton erectors and flap-folders, where the 5 um element protects valve spools from water and fine debris.
Point-of-use air preparation ahead of the stopper, pusher and gate cylinders at a conveyor divert, holding a stable set pressure so indexing stays repeatable through the shift.
Regulated, finely filtered air for grippers and sample-transfer actuators on laboratory automation, where the 5 um grade and bar-reading gauge support clean, repeatable motion.
Start with the port and size: this unit steps down to 1/4 in NPT, so match it to the air consumption of the tools or cylinders it feeds, and step up to a 300, 400 or 600 GFR if the line needs more flow. The 5 um element here suits paint, instrumentation and other dirt- and water-sensitive duties; choose the 40 um standard grade where general plant air is acceptable. Drain choice matters: differential-pressure (as fitted) needs no timer or operator, automatic suits unattended duty, and manual suits intermittent use. Gauge scale (MPa, psi or bar), thread family (PT standard, G or NPT to order) and the bracket option are all decodable choices - this unit is supplied without a bracket and with a round bar gauge. Because flow is published as curves and not a single rating, send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number here. Tell us your application and we will confirm the flow and sizing figures from the datasheet on request before you order.
The W code in this model selects the 5 um filtration grade, the finer of the two catalogue options, for duties where water carryover and fine particulate matter - such as paint, instrumentation or valve protection. The 40 um grade remains the standard choice for general plant air, and both grades are available across the GFR range.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.