The AirTAC GFR200C08MLNWTK AirTAC Filter Regulator NPT1/4 5um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR200C08MLNWTK is an AirTAC GFR200 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is built with a 1/4 in NPT port, the finer 5 um filter element, a manual drain on the bowl, a fitted reverse/check valve, and an included mounting bracket. It is the low-pressure regulator type and is supplied without a gauge; a gauge can be added on other codes.
This is a genuine AirTAC part from the GFR series, which spans sizes 200 to 600 with ports from 1/8 to 1 in and PT, G or NPT threads. Maximum inlet pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and any datasheet figure for your application before ordering.
| Model | GFR200C08MLNWTK AirTAC Filter Regulator NPT1/4 5um |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Condition and regulate the air feeding a bank of directional control valves on a packaging machine, with the check valve holding the circuit if the upstream supply drops.
Feed the gripper and suction circuits of a small pick-and-place cell from a low-pressure regulated drop, with 5 um air protecting the pilot valves from dirt and water.
Set up a conditioned workbench drop on a small assembly line, giving operators filtered, regulated air at the tool connection without running a separate filter and regulator.
The decodable choices on this unit: size 200 with a 1/4 in NPT port suits circuits plumbed at 1/4 in; step up to sizes 300, 400 or 600 for larger ports and more flow. The 5 um element (code W) is the finer option versus the standard 40 um, so choose it where downstream valves and cylinders need cleaner air. Drain is manual (code M), meaning the bowl is bled by hand on a routine; automatic and differential-pressure drains exist on other codes if the drop is unattended. The fitted reverse/check valve (code K) holds the downstream side if supply pressure drops. Thread here is NPT; PT is the standard and G (BSPP) can be ordered. No gauge is fitted on this code. Flow is published as curves, not a single rating, so send us your flow and pressure requirements and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number here. Send us your required flow and working pressure and we will confirm sizing against the datasheet on request.
Code M fits a manual drain: the bowl is bled by hand on a routine, which suits point-of-use drops where someone is already at the machine. If the drop runs unattended, look at the automatic (A) or differential-pressure (blank) drain codes instead.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.