The AirTAC GFR200C08MNT AirTAC Filter Regulator 1/4 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR200C08MNT is a size 200 filter regulator: it removes water and particulate from compressed air and holds downstream pressure steady, in one compact body. This configuration carries a 1/4 in NPT port, a 40 um standard filter element, a manual drain bowl in polycarbonate (PC), a standard regulator adjustable from 0.05 to 0.9 MPa (7-130 psi), and a mounting bracket. No gauge is fitted with this code, so pair it with your preferred pressure gauge if a visual setpoint is needed.
This is a genuine AirTAC part from the GFR filter-regulator family, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of manual, automatic or differential-pressure drains, an optional 5 um element (code W), gauge options, and PT, G or NPT threads. Rated inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm sizing figures from the datasheet for your application.
| Model | GFR200C08MNT AirTAC Filter Regulator 1/4 in NPT |
|---|---|
| Series | GFR200 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR200 | G-series filter regulator, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR200 · See datasheet · 40 µm |
|---|---|
| One size up | GFR300 |
| Add lubrication | GFC200-C0 (two-unit set) |
Filtered, regulated air feeding the diverter and stopper cylinders that route cartons between conveyor lanes, with the manual drain bled during shift changeover.
Conditioning the supply to pneumatic jet and doffing circuits on knitting and spinning frames, where steady pressure keeps the sequence repeatable.
Point-of-use air preparation for benchtop analyser and sample-handling skids, where the 40 um element protects pilot valves from water and pipe scale.
Start with the port step: size 200 with a 1/4 in NPT port suits lighter branch lines; step up to sizes 300, 400 or 600 when the line demands more flow. Choose the drain to match access: this unit has a manual drain, best where an operator can bleed the bowl on a routine walk-round; choose automatic or differential-pressure drain codes where the unit sits in an inaccessible spot. The standard element is 40 um; specify the W code for the 5 um grade when downstream valves or instruments need finer filtration. This code ships without a gauge; gauge options and pressure scales can be selected on related codes. Thread is NPT here, with PT (the standard) and G also available to order, and a mounting bracket is included. Because flow is published as curves rather than a single rated figure, send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Tell us your line pressure and the flow your application needs, and we will confirm the correct size against the datasheet before you order.
The M in the code is the manual drain: condensate collected in the polycarbonate bowl is released by operating the drain by hand, which suits units mounted where an operator passes regularly. This code (N) carries no gauge, so add a separate pressure gauge if you need to read the regulated setpoint; the regulation range for this manual-drain unit is 0.05-0.9 MPa (7-130 psi).
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.