verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR200 · Filter Regulator (filter + regulator in one body)

GFR200C08NTK AirTAC Filter Regulator NPT1/4

The AirTAC GFR200C08NTK AirTAC Filter Regulator NPT1/4 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$47.83 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR200C08NTK AirTAC Filter Regulator NPT1/4

The GFR200C08NTK is an AirTAC GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single compact body. This unit is the size 200 frame with a 1/4 in NPT port, standard 40 um filtration, and a differential-pressure drain that bleeds collected condensate automatically whenever the pressure differential across the element is high enough. The built-in check (reverse) valve holds downstream settings if upstream supply is interrupted. Outlet pressure is adjustable over 0.15-0.9 MPa (20-130 psi), with a maximum inlet pressure of 1.0 MPa (145 psi), and the polycarbonate bowl suits ambient temperatures of -5 to 70 C (non-freezing). No gauge is fitted in this configuration, so add a gauge separately if a visual pressure readout is required.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drains, 40 um or 5 um (W) filtration grades, gauge and bracket options, and PT, G or NPT threads. Because AirTAC publishes flow only as curves rather than a single rated figure, we confirm the datasheet and flow data for your exact operating conditions on request.

GFR200C08NTK AirTAC Filter Regulator NPT1/4 Technical Specifications

ModelGFR200C08NTK AirTAC Filter Regulator NPT1/4
SeriesGFR200 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR200C08NTK AirTAC Filter Regulator NPT1/4

GFR200G-series filter regulator, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR200 · See datasheet · 40 µm
One size upGFR300
Add lubricationGFC200-C0 (two-unit set)

Where the GFR200C08NTK AirTAC Filter Regulator NPT1/4 Is Used

precision_manufacturing

CNC machine tool air supply

Point-of-use conditioning for a machining centre's pneumatic actuators and tool-change clamps: the filter stage strips water and chips-laden particulate from the shop-air drop, while the regulator holds a steady clamp pressure and the check valve keeps the setting if the main supply dips.

conveyor_belt

Packaging line diverters and sealers

Feeding air cylinders on a carton packaging conveyor, where clean, dry-ish air at a stable pressure keeps diverters and sealing jaws cycling consistently. The differential-pressure drain sheds accumulated condensate without a manual walk-round, and the 40 um element protects directional valves.

factory

Assembly station air drops

A workbench drop on a factory assembly line running air tools and small actuators: the GFR200C08NTK filters the incoming supply, regulates it to the station's working pressure, and the built-in check valve prevents backfeed between adjacent stations sharing a header.

Is the GFR200C08NTK AirTAC Filter Regulator NPT1/4 the Right Unit?

Start with the port and size step: this unit is size 200 with a 1/4 in NPT port, and the GFR range steps up through 300, 400 and 600 as flow demand grows - match the step to your line's air consumption rather than port size alone. Choose the drain to suit access: this configuration uses the differential-pressure drain (the default), while automatic (A) and manual (M) drains are available if your duty or maintenance routine calls for them. Filtration is the standard 40 um grade; specify the W variant for 5 um if downstream equipment needs finer protection. Note that no gauge is fitted (code N) and a check valve is included (code K); gauge, scale and bracket options can be selected on other configurations. Thread is NPT here, with PT as the catalogue standard and G (BSPP) also available to order. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR200C08NTK AirTAC Filter Regulator NPT1/4 FAQ

AirTAC publishes flow for the GFR series as performance curves rather than a single rated number, so we do not quote a rated flow, Cv or SCFM figure. Tell us your inlet pressure, set pressure and required air consumption, and we will confirm the flow data from the datasheet for this exact model before you order.

The N in GFR200C08NTK means no pressure gauge is fitted; gauge options (round or square, with MPa, psi or bar scales) are available on other GFR configurations if you want a visual readout. The K means a reverse (check) valve is fitted, which holds the downstream pressure setting if the upstream supply is interrupted.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR200C08NTK AirTAC Filter Regulator NPT1/4

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR200C08NTK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.