verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR300 · Filter Regulator (filter + regulator in one body)

GFR300-08 AirTAC Filter Regulator 1/4 in NPT

The AirTAC GFR300-08 AirTAC Filter Regulator 1/4 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/4" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$52.66 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR300-08 AirTAC Filter Regulator 1/4 in NPT

The AirTAC GFR300-08 is a size-300 filter regulator that removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration has a 1/4 in NPT port, a manual drain bowl in polycarbonate, a standard 40 um filter element, an embedded square gauge with a psi scale, a reverse/check valve, and the included mounting bracket. The regulator adjusts from 0.05 to 0.9 MPa (7-130 psi), and the unit handles a maximum inlet pressure of 1.0 MPa (145 psi) at -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GFR line is available in sizes 200, 300, 400 and 600 with port options, drain types (differential-pressure, automatic or manual), a 5 um filter element option, gauge scale choices and G/NPT thread options. Flow is published as curves rather than a single rating, so we confirm the datasheet figures for your application on request.

GFR300-08 AirTAC Filter Regulator 1/4 in NPT Technical Specifications

ModelGFR300-08 AirTAC Filter Regulator 1/4 in NPT
SeriesGFR300 filter regulator
Port sizePT1/4" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR300-08 AirTAC Filter Regulator 1/4 in NPT

GFR300G-series filter regulator, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · PT1/4" · 40 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-08 (two-unit set)

Where the GFR300-08 AirTAC Filter Regulator 1/4 in NPT Is Used

precision_manufacturing

CNC machining centre air supply

Filtering and regulating the shop-air feed to a CNC machine's pneumatic tool-changer and clamping circuits, with the psi gauge giving operators a local setpoint readout.

conveyor_belt

Packaging line cylinder supply

Conditioning air ahead of the cylinders and diverters on a carton packaging conveyor, where the check valve holds the downstream setting if supply pressure dips.

factory

Assembly-cell actuator feed

Supplying cleaned, regulated air to the grippers and press cylinders in a small-parts assembly cell, with the manual drain emptied during scheduled shift checks.

Is the GFR300-08 AirTAC Filter Regulator 1/4 in NPT the Right Unit?

Start with the size and port: the 300 size with a 1/4 in NPT port suits lines running at this connection scale, and larger sizes give larger ports and more flow. Choose the drain to match maintenance access: manual drain (this unit) needs someone to open it, while automatic and differential-pressure drains discharge condensate without a manual step. The standard element is 40 um; select the 5 um (W) element where finer filtration is needed. Gauge scale is selectable (MPa, psi or bar), and PT is the standard thread with G and NPT as order options. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR300-08 AirTAC Filter Regulator 1/4 in NPT FAQ

AirTAC publishes flow for this series as curves rather than a single rated figure, so we do not quote a number. Tell us your application and we will confirm the datasheet flow figures for you on request.

The M in the code specifies a manual drain bowl: condensate is released by opening the drain by hand as part of routine checks. The GFR300 is also available with a differential-pressure drain (default) or an automatic drain (code A) if you prefer unattended condensate removal.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR300-08 AirTAC Filter Regulator 1/4 in NPT

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR30008MF2TK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.