verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR300 · Filter Regulator (filter + regulator in one body)

GFR300-08 AirTAC Filter Regulator, G1/4, 5 um, Low-Pressure

The AirTAC GFR300-08 AirTAC Filter Regulator, G1/4, 5 um, Low-Pressure is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/4" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$52.48 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR300-08 AirTAC Filter Regulator, G1/4, 5 um, Low-Pressure

The AirTAC GFR300-08 is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This 300-size unit is fitted with a G1/4 (BSPP) port, a 5 um filter element for finer filtration than the 40 um standard, a manual drain for emptying the PC bowl, the low-pressure regulator type, a round external gauge with psi scale, and a reverse/check valve that holds downstream pressure when the supply is lost. The mounting bracket is included. Maximum working (inlet) pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part from the G-series filter regulator line, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 inch, a choice of 40 um or 5 um filtration, manual, automatic or differential-pressure drains, standard or low-pressure regulation, gauge and scale options, and PT, G or NPT threads. Flow is published as curves rather than a single rating, so ask us to confirm flow and datasheet figures for your application before ordering.

GFR300-08 AirTAC Filter Regulator, G1/4, 5 um, Low-Pressure Technical Specifications

ModelGFR300-08 AirTAC Filter Regulator, G1/4, 5 um, Low-Pressure
SeriesGFR300 filter regulator
Port sizePT1/4" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR300-08 AirTAC Filter Regulator, G1/4, 5 um, Low-Pressure

GFR300G-series filter regulator, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · PT1/4" · 5 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-08 (two-unit set)

Where the GFR300-08 AirTAC Filter Regulator, G1/4, 5 um, Low-Pressure Is Used

precision_manufacturing

Low-pressure pneumatic clamping on a machining cell

On a CNC machining cell where soft-jaw clamps or pallet hold-downs must close at a gentle, stable set pressure, this GFR300-08 filters the shop air to 5 um and regulates it in the low-pressure band, with the check valve holding the clamp position if the main supply drops.

factory

Packaging machine low-pressure air assist

On a carton-sealing or wrapping line, low-pressure air is needed for film tensioning, counting jets and gate actuation. This unit cleans the supply to 5 um, sets the reduced pressure with a psi gauge readable at the machine, and the manual drain suits a shift-based maintenance routine.

science

Laboratory and test-bench air supply

On a lab test bench or pilot rig running sensitive pneumatic instruments, the 5 um element protects fine components from water and particulate, the low-pressure regulator type suits circuits set well below standard line pressure, and the check valve prevents backfeed between bench stations.

Is the GFR300-08 AirTAC Filter Regulator, G1/4, 5 um, Low-Pressure the Right Unit?

Choose the 300 size with its 1/4 in port when your line sits in the middle of the G-series flow range; step up to 400 or 600 for larger demand, or down to 200 for compact circuits. This unit carries the 5 um (W) element, so pick it over the 40 um standard grade when downstream valves, cylinders or instruments need finer air. The manual drain (M) means an operator or maintenance round empties the bowl - choose automatic or differential-pressure drain codes instead if you want the bowl to clear itself. The low-pressure (L) regulator type is intended for circuits set below the standard adjustment range; the exact range for this type is not published, so confirm it with us. The round gauge is fitted with a psi scale (MPa and bar scales are the other options). Thread here is G (BSPP); PT is the standard thread and NPT is also an order option. Bracket is included.

Flow for this family is published as curves, not a single rated figure, so we do not quote a number here - send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR300-08 AirTAC Filter Regulator, G1/4, 5 um, Low-Pressure FAQ

AirTAC publishes flow for this family as curves, not as a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow figures from the datasheet so you can size the unit against your demand before ordering.

The L code makes this a low-pressure regulator type, intended for circuits set below the standard adjustment range; the exact range for this type is not published, so confirm it with us. The K code adds a reverse/check valve, which holds downstream pressure when the upstream supply is lost. This unit also has a manual drain, so the bowl should be emptied as part of a scheduled maintenance round.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR300-08 AirTAC Filter Regulator, G1/4, 5 um, Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR30008MLC2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.