The AirTAC GFR300-08 AirTAC Filter Regulator G1/4, Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/4" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR300-08 is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This size 300 unit has a G1/4 (1/4 in) port, a manual-drain bowl in polycarbonate, and a 40 um filter element. The regulator is the low-pressure type (code L), a square pressure gauge scaled in psi is fitted, a reverse/check valve is included, and the unit comes with a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, and options across the series include automatic, manual or differential-pressure drains, a 5 um filter element (code W), gauge scales in MPa, psi or bar, G or NPT threads, and a no-bracket variant. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and datasheet figures for your application.
| Model | GFR300-08 AirTAC Filter Regulator G1/4, Low-Pressure |
|---|---|
| Series | GFR300 filter regulator |
| Port size | PT1/4" (G (BSPP) thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Low-pressure type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| G | G (BSPP) thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · PT1/4" · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-08 (two-unit set) |
Filtered, regulated air to pneumatic clamps and workholding on a machining cell, with the low-pressure regulator type matching circuits that call for that pressure class.
Clean, regulated air for cylinders and grippers on a packaging conveyor, with the manual-drain bowl emptied during scheduled line maintenance.
A compact filter regulator for lab and test-rig air supplies that need water- and particulate-free air held at a set pressure.
Size steps through 200, 300, 400 and 600 with ports from 1/8 to 1 inch; choose the step that matches your piping and the flow your line needs. Drain choices are differential-pressure (default), automatic (code A) or manual (code M) - this unit is manual, so the bowl is emptied by hand as part of routine maintenance. Filter grade is 40 um standard or 5 um with code W. Gauge scales are MPa, psi or bar; this unit carries the embedded square gauge scaled in psi, and an external round gauge is optional. Thread is PT as the standard, with G and NPT as order options - this unit is G. A bracket is included (code J omits it). Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Tell us your application and we will confirm the flow and datasheet figures for this exact model on request.
This unit carries code M, a manual drain: the bowl is emptied by hand as part of routine maintenance. The same size is available with an automatic drain (code A) or the differential-pressure drain (the default) if you would rather not drain it manually.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.