The AirTAC GFR300-08MC2WG AirTAC Filter Regulator G1/4, 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/4" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR300-08MC2WG is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one 300-size body with a G1/4 (1/4 in) port. This configuration carries a polycarbonate bowl with a manual drain, a 5 um filter element, and a round pressure gauge reading in psi. The standard regulator adjusts from 0.05-0.9 MPa (7-130 psi), maximum inlet pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing). A mounting bracket is included.
This is a genuine AirTAC part. The GFR300 series is one of four sizes (200/300/400/600) with ports stepping from 1/8 in up to 1 in, a choice of 40 um standard or 5 um filtration, manual, automatic or differential-pressure drains, and MPa, psi or bar gauge scales. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet values for your application.
| Model | GFR300-08MC2WG AirTAC Filter Regulator G1/4, 5 um |
|---|---|
| Series | GFR300 filter regulator |
| Port size | PT1/4" (G (BSPP) thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| G | G (BSPP) thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · PT1/4" · 5 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-08 (two-unit set) |
Feeds clean, moisture-reduced and pressure-regulated air to a machine tool's pneumatic circuits, protecting solenoid valves and actuator cylinders on the shop floor.
Sits at the drop point on a packaging conveyor to filter condensed water from the ring main and hold a stable set pressure for the case-forming and sealing cylinders.
Provides filtered, regulated air at each assembly cell's manifold, keeping pick-and-place grippers and clamping cylinders supplied at the pressure the fixture was set up for.
Size and port scale with air demand: the 300 size here takes a G1/4 connection, and larger 400/600 sizes step up to 3/4 and 1 inch ports. Drain type is a real choice: this unit's manual drain needs someone to open the bowl drain at intervals, while automatic and differential-pressure drains discharge condensate without attention. The 5 um element (code W) suits work needing finer filtration than the 40 um standard. The gauge on this unit reads in psi; MPa and bar scales are also available. Thread is G (BSPP); PT is the standard thread and NPT is an order option. A mounting bracket is included. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for this series as curves rather than a single rated figure, so we do not quote a number here. Ask us and we will confirm the datasheet flow curve against your application's air demand before you order.
The M in the code means the polycarbonate bowl drains by hand: someone opens the drain at intervals to release collected condensate. It suits installations that are checked routinely; automatic or differential-pressure drains are available on the same series if no one is around to drain the bowl.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.