The AirTAC GFR300-10 AirTAC Filter Regulator 3/8 in NPT, Manual Drain is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT3/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR300-10 is a 300-size filter regulator that removes water and particulate from compressed air and sets downstream pressure in a single body. This configuration is a 3/8 in NPT port unit with a manual drain on the polycarbonate bowl, the standard 40 um filter element, an embedded square gauge reading in psi, and a standard regulator adjustable from 0.05 to 0.9 MPa (7-130 psi). Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR family is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of manual, automatic or differential-pressure drain, a 5 um (W) element option, MPa/psi/bar gauge scales, and G or NPT thread options. Flow is published as curves rather than a single rating, so we confirm the datasheet and flow figures for your application on request.
| Model | GFR300-10 AirTAC Filter Regulator 3/8 in NPT, Manual Drain |
|---|---|
| Series | GFR300 filter regulator |
| Port size | PT3/8" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · PT3/8" · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-10 (two-unit set) |
Point-of-use conditioning for a cartoning or wrapping line: clean, dry air and a stable regulated pressure feeding the cylinders and actuators that form, fill and seal each pack.
Feeding the air cylinders that raise diverters, stoppers and pushers on a conveyor line, with the manual drain bowl emptied during scheduled line checks.
Conditioning the compressed air feed to a laboratory test bench or pilot rig, where the square psi gauge gives a clear local pressure readout for repeatable test settings.
Size the GFR300 by the flow your line needs: step up through 200, 300, 400 and 600 as port and flow demand grow - this 300 size carries a 3/8 in port. Choose the drain to suit access: manual (as here) suits attended installations, automatic suits unattended duty, and differential-pressure is the catalogue default. The 40 um element is standard; specify the 5 um W option where finer filtration is required. The embedded square gauge is fitted here with a psi scale (MPa and bar scales are also available), and a mounting bracket is included. Thread is NPT on this unit; PT is the standard and G (BSPP) is also an order option. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR300 as curves rather than a single rated figure, so no single number would be honest. Tell us your application and we will confirm the flow and datasheet figures for this 3/8 in unit on request before you order.
The M in the code GFR30010MF2T specifies a manual drain, so condensate is released by opening the drain by hand during routine checks. The catalogue also offers an automatic drain (code A) and a differential-pressure drain (blank) if you prefer unattended moisture removal.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.