verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR300 · Filter Regulator (filter + regulator in one body)

GFR30008ALC2K AirTAC Filter Regulator PT1/4, 1/4 in

The AirTAC GFR30008ALC2K AirTAC Filter Regulator PT1/4, 1/4 in is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/4" ports, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$62.81 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR30008ALC2K AirTAC Filter Regulator PT1/4, 1/4 in

The AirTAC GFR30008ALC2K is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body, so one 1/4 in (PT1/4) unit does both jobs in the air-prep position. This configuration is the size-300 GFR with an automatic drain that ejects collected condensate without manual attention, a 40 um standard filter element, the low-pressure regulator type, a round pressure gauge reading in psi, and a reverse/check valve fitted to hold downstream pressure if the supply drops. Maximum inlet pressure is 1.0 MPa (145 psi), the polycarbonate bowl suits -5 to 70 C (non-freezing) service, and a mounting bracket is included.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drain, a 5 um optional element (code W), embedded square or external round gauges with MPa, psi or bar scales, and G or NPT thread options to order. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application.

GFR30008ALC2K AirTAC Filter Regulator PT1/4, 1/4 in Technical Specifications

ModelGFR30008ALC2K AirTAC Filter Regulator PT1/4, 1/4 in
SeriesGFR300 filter regulator
Port sizePT1/4" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR30008ALC2K AirTAC Filter Regulator PT1/4, 1/4 in

GFR300G-series filter regulator, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · PT1/4" · 40 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-08 (two-unit set)

Where the GFR30008ALC2K AirTAC Filter Regulator PT1/4, 1/4 in Is Used

precision_manufacturing

Pick-and-place robot air prep

Feeding the valve manifold of a pneumatic pick-and-place cell on an assembly line: the 40 um element stops particulate reaching the directional valves, the regulator holds a steady low-pressure supply for gentle gripper action, and the automatic drain keeps condensate out of the circuit without operator rounds.

settings_input_component

Packaging machine supply station

Mounting at the air inlet of a cartoning or wrapping machine: one 1/4 in body filters the shop air and regulates it for the machine's low-pressure actuators, the check valve holds the setting through brief supply dips, and the psi gauge lets the line technician verify the set point at a glance.

factory

Textile loom service line

Conditioning air on individual loom supply drops in a weaving shed: the automatic drain copes with the heavy moisture load typical of continuous compressed-air lines, the low-pressure regulator type matches loom actuation pressures, and the included bracket fixes the unit cleanly to the machine frame.

Is the GFR30008ALC2K AirTAC Filter Regulator PT1/4, 1/4 in the Right Unit?

Start with the port step: this unit is size 300 with a 1/4 in PT port; step up to size 400 or 600 when downstream demand calls for a larger port, and match the thread to your piping - PT is the standard here, with G (BSPP) and NPT available as order options. For the drain, automatic (this unit) suits points that are not checked daily; manual drain suits attended stations; the differential-pressure default triggers on the pressure drop across the element. The 40 um element is the standard grade; specify the W code for 5 um where finer filtration is needed. Gauge scale (MPa, psi or bar - this unit reads psi) and the reverse/check valve (fitted here, code K) are the remaining decodable choices.

One honest note on sizing: AirTAC publishes flow for this family as curves, not as a single rated number, and the exact regulation range of the low-pressure type is not stated in the published data. Send us your line pressure, required downstream setting and air demand, and we will confirm the datasheet figures and the right size before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR30008ALC2K AirTAC Filter Regulator PT1/4, 1/4 in FAQ

AirTAC publishes flow for the GFR family as performance curves rather than a single rated figure, so there is no one l/min or SCFM number we can honestly quote for this 1/4 in unit. Tell us your inlet pressure and the air demand of your equipment, and we will confirm the datasheet curve and check the sizing against your application before you order.

The L in GFR30008ALC2K marks the low-pressure regulator type, intended for downstream settings below what the standard type targets. The exact adjustment range for the low-pressure GFR is not stated in the published data, so we do not quote a figure here - send us your required downstream pressure and we will confirm suitability from the datasheet. Everything else about the unit is fixed by the code: automatic drain, 40 um element, round psi gauge, check valve fitted, PT1/4 port.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR30008ALC2K AirTAC Filter Regulator PT1/4, 1/4 in

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR30008ALC2K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.