verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR300 · Filter Regulator (filter + regulator in one body)

GFR30008JC2WK AirTAC Filter Regulator PT1/4, 5 um

The AirTAC GFR30008JC2WK AirTAC Filter Regulator PT1/4, 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/4" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$51.19 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR30008JC2WK AirTAC Filter Regulator PT1/4, 5 um

The GFR30008JC2WK is an AirTAC GFR300 filter regulator: water and particulate filtration plus pressure regulation combined in a single body. This configuration has 1/4 in PT ports, a 5 um filter element (the finer of the two published grades - 40 um standard, 5 um optional with code W), a differential-pressure drain on the bowl, and a round pressure gauge reading in psi. A reverse/check valve is fitted, and the unit is supplied without a mounting bracket. The regulator is the standard type with an adjustment range of 0.15-0.9 MPa (20-130 psi) with this differential-pressure drain. Maximum inlet pressure is 1.0 MPa (145 psi), the operating temperature range is -5 to 70 C (non-freezing), and the polycarbonate bowl suits this 300 size (only the 600 size uses an aluminium alloy bowl).

This is a genuine AirTAC part. The GFR filter-regulator family is available in sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, in PT (standard), G and NPT threads, with manual, automatic or differential-pressure drains, 40 um or 5 um filtration, and a choice of gauge and scale. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application on request.

GFR30008JC2WK AirTAC Filter Regulator PT1/4, 5 um Technical Specifications

ModelGFR30008JC2WK AirTAC Filter Regulator PT1/4, 5 um
SeriesGFR300 filter regulator
Port sizePT1/4" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR30008JC2WK AirTAC Filter Regulator PT1/4, 5 um

GFR300G-series filter regulator, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · PT1/4" · 5 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-08 (two-unit set)

Where the GFR30008JC2WK AirTAC Filter Regulator PT1/4, 5 um Is Used

precision_manufacturing

CNC machining centre air prep

Feeding clean, regulated air to pneumatic clamps, tool-change cylinders and chip-clearing nozzles on a machining centre, with the 5 um element protecting fine control valves upstream of the spindle area.

settings_input_component

Packaging machine actuator supply

Conditioning the air supply to a form-fill-seal or cartoning line, where the regulator holds a steady setting for sealing and product-push cylinders and the drain carries condensed water out of the bowl.

conveyor_belt

Pick-and-place stations on conveyor lines

Supplying regulated air to gripper and lift cylinders at pick-and-place stations along a conveyor system, with the reverse/check valve helping hold the downstream circuit if the upstream supply is interrupted.

Is the GFR30008JC2WK AirTAC Filter Regulator PT1/4, 5 um the Right Unit?

The real choices on this family are the size and port step (200/300/400/600, 1/8 in to 1 in) matched to the air demand of your circuit; the drain type (differential-pressure as here, automatic, or manual); the filter grade (40 um standard or 5 um with code W); the gauge style and scale (MPa, psi or bar); and the thread (PT standard, with G and NPT as order options). This unit is configured with a 5 um element, a differential-pressure drain, a psi-scale round gauge and a reverse/check valve, without a mounting bracket. Because flow is published as curves rather than one rated figure, send us your application details and we will confirm sizing against the AirTAC datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR30008JC2WK AirTAC Filter Regulator PT1/4, 5 um FAQ

Flow for the GFR300 series is published as curves, not as a single rated number, so we do not quote a figure here. Send us your application details - port size, line pressure and the air demand of the downstream equipment - and we will confirm the sizing from the AirTAC datasheet on request.

The W selects the 5 um filter element instead of the 40 um standard grade. Choose 5 um where downstream valves, cylinders or instruments need finer filtration; 40 um suits general plant air. Both grades are catalogue options across the GFR filter-regulator family.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR30008JC2WK AirTAC Filter Regulator PT1/4, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR30008JC2WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.