The AirTAC GFR30008MLJNT AirTAC Filter Regulator NPT1/4 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/4" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR30008MLJNT is a GFR-series filter regulator: it removes water and particulate from compressed air and holds downstream pressure at a set point in one compact body. This unit is built on the GFR300 size with 1/4 in NPT ports, a manual drain bowl in polycarbonate, and a 40 um standard filter element. It is the low-pressure regulation type, supplied without a gauge and without a mounting bracket.
This is a genuine AirTAC part from the G-series range, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 in and PT, G or NPT threads. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm datasheet figures for your application before ordering.
| Model | GFR30008MLJNT AirTAC Filter Regulator NPT1/4 Low-Pressure |
|---|---|
| Series | GFR300 filter regulator |
| Port size | PT1/4" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Low-pressure type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · PT1/4" · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-08 (two-unit set) |
On a paint or coating line, the low-pressure regulator holds a gentle, stable supply to the spray gun while the 40 um element and manual drain keep water out of the finish.
Feed clamp cylinders on a CNC fixture or workholding jig: the filter section protects the valves from dirt and water, and the regulator sets the clamping circuit pressure.
As a compact first stage on a packaging or labeling machine, it cleans and regulates the air feeding directional valves and small actuators, with the manual drain emptied during shift checks.
The real choices on this family are the size and port step (200/300/400/600 against the flow your line needs), the drain type - differential-pressure as standard, automatic, or the manual drain fitted here - the filter grade (40 um standard, 5 um with code W), the gauge and its scale, and the thread (PT standard, G and NPT as order options). This unit is the low-pressure regulation type with no gauge and no bracket. Flow is published as curves, not a single rated figure, so send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR300 as curves, not as a single rated figure, so we do not quote a number here. Send us your line pressure and air demand and we will confirm the sizing from the datasheet on request.
The M in the code selects a manual drain: the bowl is emptied by hand during routine checks instead of draining automatically. The L selects the low-pressure regulation type; its exact setting range is not published on the sheet, so confirm it with us before ordering. This unit has no gauge fitted and no mounting bracket.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.