The AirTAC GFR30010ALJF2G AirTAC Low-Pressure Filter Regulator G3/8 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT3/8" ports, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR30010ALJF2G is a filter regulator: filtration and pressure regulation combined in one body, removing water and particulate from compressed air and then regulating the pressure delivered downstream. This configuration is size 300 with a G3/8 threaded port, an automatic drain that expels collected condensate without operator attention, the standard 40 um filter element, and the low-pressure regulator variant. The embedded square gauge reads in psi, and no mounting bracket is fitted.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, and options across the range include manual or differential-pressure drains, a 5 um element (code W), gauge scales in MPa, psi or bar, PT, G or NPT threads, and a mounting bracket. Flow is published as curves rather than a single rating, so ask us to confirm datasheet figures for your application before ordering.
| Model | GFR30010ALJF2G AirTAC Low-Pressure Filter Regulator G3/8 |
|---|---|
| Series | GFR300 filter regulator |
| Port size | PT3/8" (G (BSPP) thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| G | G (BSPP) thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · PT3/8" · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-10 (two-unit set) |
Feeding cleaned, regulated air to the cylinder bank of a carton-sealing line, with the automatic drain handling condensate through continuous production shifts.
Supplying a pneumatic clamping fixture on a machining cell where the workpiece calls for a lower holding pressure than a standard regulator setting provides.
Conditioning air for the stopper and pusher cylinders along a bottling conveyor, filtering out water and particulate before it reaches the directional valves.
Step through the GFR range by size (200/300/400/600) and port (1/8 to 1 inch) against the flow your line needs; this unit is size 300 with a G3/8 port. Drain choice is differential-pressure (default), automatic (fitted here) or manual; filter grade is 40 um standard or 5 um with code W. Gauge scale is selectable in MPa, psi or bar (this unit reads psi), thread is PT as standard with G and NPT as order options, and a bracket is optional (not fitted on this code). Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow and the full datasheet figures for GFR30010ALJF2G on request.
This unit carries drain code A: an automatic drain that expels collected condensate from the PC bowl without operator attention. The GFR family is also available with a manual drain or the default differential-pressure drain - tell us which you prefer when ordering.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.