verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR300 · Filter Regulator (filter + regulator in one body)

GFR30010MF2G AirTAC Filter Regulator, G3/8, Manual Drain

The AirTAC GFR30010MF2G AirTAC Filter Regulator, G3/8, Manual Drain is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT3/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT3/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$40.94 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR30010MF2G AirTAC Filter Regulator, G3/8, Manual Drain

The AirTAC GFR30010MF2G is a filter regulator: it removes water and particulate from compressed air and holds downstream pressure steady in one compact body. This 300-size unit is fitted with a G3/8 (BSPP) port, a manual drain on the PC bowl, a 40 um filter element and an embedded square gauge reading in psi. The regulator adjusts from 0.05 to 0.9 MPa (7-130 psi), the maximum inlet pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing). A mounting bracket is included.

This is a genuine AirTAC part. The GFR family is available in sizes 200, 300, 400 and 600, with a choice of drain type (differential-pressure, automatic or manual), a 5 um element option (code W), gauge scales in MPa, psi or bar, and PT, G or NPT threads. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.

GFR30010MF2G AirTAC Filter Regulator, G3/8, Manual Drain Technical Specifications

ModelGFR30010MF2G AirTAC Filter Regulator, G3/8, Manual Drain
SeriesGFR300 filter regulator
Port sizePT3/8" (G (BSPP) thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR30010MF2G AirTAC Filter Regulator, G3/8, Manual Drain

GFR300G-series filter regulator, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · PT3/8" · 40 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-10 (two-unit set)

Where the GFR30010MF2G AirTAC Filter Regulator, G3/8, Manual Drain Is Used

conveyor_belt

Packaging line air prep

Feeding filtered, regulated air to the cylinder and vacuum circuits that drive carton sealers and case packers on a packaging line.

precision_manufacturing

Pneumatic press station

Supplying clean air at a set pressure to a bench-mounted pneumatic press or clamping fixture, with the psi gauge giving operators a visible setpoint.

science

Lab automation skid

Conditioning the air supply to sample-handling cylinders and valves on a laboratory automation skid where a stable, regulated pressure matters.

Is the GFR30010MF2G AirTAC Filter Regulator, G3/8, Manual Drain the Right Unit?

Step up or down through the 200/300/400/600 sizes to match the port and flow your line needs - this unit sits at 300 with a 3/8 in G thread. Drain type is a real choice: manual (as here) needs an operator to bleed the bowl, while differential-pressure and automatic drains handle it for you. The 40 um element is standard; specify the W code for 5 um where finer filtration matters. Gauge scale (MPa, psi or bar), thread (PT standard, G or NPT to order) and the bracket are all decodable from the code. Flow is published as curves, not a single rating, so let us confirm sizing against your application before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR30010MF2G AirTAC Filter Regulator, G3/8, Manual Drain FAQ

AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the datasheet flow curves and sizing for this 3/8 in unit before you order.

The M code in this model specifies a manual drain: an operator opens the drain to bleed collected water from the PC bowl. The same GFR300 body is available with a differential-pressure drain (the default) or an automatic drain (code A) if you prefer unattended operation.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR30010MF2G AirTAC Filter Regulator, G3/8, Manual Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR30010MF2G and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.