The AirTAC GFR30015JF1T AirTAC Filter Regulator NPT1/2 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/2" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR300 is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration is ordered with NPT1/2 ports, a 40 um filter element, a differential-pressure drain, an embedded square gauge scaled in MPa, and no mounting bracket. The polycarbonate bowl shows condensate build-up at a glance, the standard regulator holds settings from 0.15 to 0.9 MPa (20-130 psi), and the unit handles a maximum inlet pressure of 1.0 MPa (145 psi) at -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, and options include automatic or manual drains, a 5 um element (code W), psi or bar gauge scales, G or NPT threads, a reverse/check valve, and a mounting bracket. Flow is published as curves rather than a single rating, so we confirm flow and other datasheet figures on request.
| Model | GFR30015JF1T AirTAC Filter Regulator NPT1/2 |
|---|---|
| Series | GFR300 filter regulator |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · PT1/2" · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-15 (two-unit set) |
Point-of-use filter regulator on the air drop feeding a CNC machining center, drying and filtering the supply and holding a steady setting for clamps, tool changers and pneumatic doors.
Mounted ahead of the cylinders and diverters on a carton-forming packaging line, conditioning the air and keeping the regulated pressure the line was set up for, shift after shift.
A filter regulator at the workshop air drop feeding impact wrenches, air ratchets and blow guns, keeping water and scale out of the tools and the set pressure where the technicians left it.
Size and port scale with required flow: this is size 300 with a 1/2 inch NPT port. The real choices on this family are drain type (differential-pressure as here, automatic, or manual), filter grade (40 um standard, 5 um with W), gauge scale (MPa as here, or psi or bar), thread (PT standard, G or NPT to order), reverse/check valve, and bracket. Regulation range tracks the drain: 0.15-0.9 MPa (20-130 psi) with the differential-pressure or automatic drain, 0.05-0.9 MPa (7-130 psi) with manual. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
Flow for the GFR300 series is published as curves, not as a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the sizing from the AirTAC datasheet on request.
A blank drain code on the GFR family is the differential-pressure type, which uses the pressure drop across the element to bleed condensate from the bowl. Automatic (A) and manual (M) drains are order options; with a manual drain the regulation range widens to 0.05-0.9 MPa (7-130 psi).
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.