verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR300 · Filter Regulator (filter + regulator in one body)

GFR30015LF2WGK AirTAC Filter Regulator G1/2 5 um

The AirTAC GFR30015LF2WGK AirTAC Filter Regulator G1/2 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/2" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$52.10 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR30015LF2WGK AirTAC Filter Regulator G1/2 5 um

The GFR30015LF2WGK is an AirTAC GFR300 filter regulator: one body that removes water and particulate from compressed air through a 5 um element and regulates downstream pressure. This configuration is the low-pressure type (code L), intended for circuits that run below standard line pressure. It has a G1/2 (BSPP) port, a 5 um filter grade (code W), a differential-pressure drain on the PC (polycarbonate) bowl, an embedded square gauge reading in psi, a fitted reverse/check valve (code K), and the mounting bracket included. Maximum inlet pressure is 1.0 MPa (145 psi) and operating temperature is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GFR family spans sizes 200 to 600 with ports from 1/8 to 1 inch, a choice of differential-pressure, automatic or manual drain, 40 um standard or 5 um filtration, standard or low-pressure regulation, gauge scales in MPa, psi or bar, and PT, G or NPT threads. Flow is published as curves rather than a single rating, so send us your application and we will confirm the figures from the datasheet before you order.

GFR30015LF2WGK AirTAC Filter Regulator G1/2 5 um Technical Specifications

ModelGFR30015LF2WGK AirTAC Filter Regulator G1/2 5 um
SeriesGFR300 filter regulator
Port sizePT1/2" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR30015LF2WGK AirTAC Filter Regulator G1/2 5 um

GFR300G-series filter regulator, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · PT1/2" · 5 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-15 (two-unit set)

Where the GFR30015LF2WGK AirTAC Filter Regulator G1/2 5 um Is Used

valve

Low-pressure pneumatic clamping circuit

On a welding or assembly fixture that runs its clamps below standard line pressure, this unit filters the supply to 5 um to protect directional valves and regulates the reduced working pressure, with the fitted check valve covering back-flow protection at the station.

science

Coating and spray-booth air preparation

A paint or coating line needs clean, moisture-free air at a controlled reduced pressure for spray guns and atomizing air. The 5 um element keeps particulate out of the finish, and the low-pressure regulator type matches circuits that operate below standard plant pressure.

conveyor_belt

Packaging machine actuation and blow-off

On a carton-sealing or labelling conveyor, this unit conditions the air feeding cylinders and low-pressure blow-off nozzles: water and 5 um-grade particulate are drained off before they reach the valves, and downstream pressure is set at the machine rather than at the compressor room.

Is the GFR30015LF2WGK AirTAC Filter Regulator G1/2 5 um the Right Unit?

Size and port step up with air demand: this unit is size 300 with a G1/2 port, and smaller 200 or larger 400/600 bodies exist if your line needs less or more air. The 5 um element (code W) suits instrument air, valves and coating work; the 40 um standard element is enough for general plant air. Drain is differential-pressure here; automatic (A) or manual (M) versions are available. The square gauge reads psi, with MPa and bar scales as options and an external round gauge available. Thread is G (BSPP); PT and NPT are catalogue options to order. Bracket included. Because AirTAC publishes flow as curves, not a single rated figure, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR30015LF2WGK AirTAC Filter Regulator G1/2 5 um FAQ

AirTAC publishes GFR300 flow as curves rather than a single rated figure, so we do not quote a number here. Send us your required flow and working pressure and we will confirm suitability from the datasheet before you order.

L marks the low-pressure regulator type, intended for circuits that run below standard line pressure. The exact setpoint range for this version is not published in the standard table, so we confirm it from the datasheet on request. The standard (non-L) GFR versions carry the published adjustment range.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR30015LF2WGK AirTAC Filter Regulator G1/2 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR30015LF2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.