The AirTAC GFR30015MF1WTK AirTAC Filter Regulator NPT1/2 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/2" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR30015MF1WTK is an AirTAC GFR300 filter regulator: one body that removes water and particulate from compressed air and regulates downstream pressure. This configuration has a 1/2 in NPT port, a 5 um filter element (the finer of the two grades), a manual-drain polycarbonate bowl, an embedded square gauge scaled in MPa, a fitted reverse/check valve, and a mounting bracket. Its regulating range is 0.05-0.9 MPa (7-130 psi), maximum inlet pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR family is offered in sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, PT as the standard thread and G or NPT as order options, plus drain, filter-grade, gauge-scale and check-valve choices to match the line. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.
| Model | GFR30015MF1WTK AirTAC Filter Regulator NPT1/2 5 um |
|---|---|
| Series | GFR300 filter regulator |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · PT1/2" · 5 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-15 (two-unit set) |
Filtered and regulated air for the pneumatic cylinders and grippers on a carton-forming and sealing line, with the check valve holding the set pressure if the upstream supply dips.
Clean, pressure-set air feeding the tool-changer and clamping circuits of a CNC machining centre, where the 5 um element protects close-tolerance pneumatic components.
Regulated air to the diverters, stop gates and pushers along a sorting conveyor, with the manual-drain bowl emptied during scheduled line maintenance rounds.
Size steps from 200 to 600 as port and flow demand grow; this unit is size 300 with a 1/2 in NPT port. The 5 um element suits points where finer particulate control matters; the 40 um standard grade is the alternative if fine filtration is not required. Manual drain means condensate is emptied from the bowl by hand, unlike the automatic or differential-pressure drain options in the family. The embedded square MPa gauge is standard, with psi or bar scales and an external round gauge available, and the fitted check valve holds downstream settings when upstream supply drops. Because flow is published as curves and not a single rated figure, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR300 as curves rather than a single rated figure, so we do not quote one number here. Tell us your application and we will confirm the datasheet flow figures for this 1/2 in NPT, 5 um configuration on request.
The M in the code means the polycarbonate bowl is drained by hand: an operator opens the drain during maintenance rounds. It suits installations where someone is on site regularly. If you need condensate removed without manual attention, the GFR300 family also offers automatic and differential-pressure drain options.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.