verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR300 · Filter Regulator (filter + regulator in one body)

GFR30015MLC1T AirTAC Filter Regulator 1/2 in NPT

The AirTAC GFR30015MLC1T AirTAC Filter Regulator 1/2 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/2" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$40.84 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR30015MLC1T AirTAC Filter Regulator 1/2 in NPT

The AirTAC GFR30015MLC1T is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This unit is built on the GFR300 size with a 1/2 in NPT port, a polycarbonate bowl with manual drain, and a 40 um filter element. It is the low-pressure regulator type, fitted with an external round gauge reading in MPa, and includes a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, a choice of manual, automatic or differential-pressure drains, 40 um standard or 5 um (W) filtration, gauge and thread options, and standard or low-pressure regulation. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application.

GFR30015MLC1T AirTAC Filter Regulator 1/2 in NPT Technical Specifications

ModelGFR30015MLC1T AirTAC Filter Regulator 1/2 in NPT
SeriesGFR300 filter regulator
Port sizePT1/2" (NPT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR30015MLC1T AirTAC Filter Regulator 1/2 in NPT

GFR300G-series filter regulator, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · PT1/2" · 40 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-15 (two-unit set)

Where the GFR30015MLC1T AirTAC Filter Regulator 1/2 in NPT Is Used

factory

Packaging line air prep

Feeding clean, regulated air to the cylinders and actuators on a carton-forming and sealing line, with the manual drain emptied during shift checks.

precision_manufacturing

CNC clamping circuits

Supplying filtered, pressure-controlled air to pneumatic clamps and workholding fixtures on a machining cell, with the MPa gauge read at a glance.

valve

Low-pressure pilot circuits

Regulating supply to pneumatic valves and pilot circuits that run below standard plant pressure, where the low-pressure regulator type is the right choice.

Is the GFR30015MLC1T AirTAC Filter Regulator 1/2 in NPT the Right Unit?

The real, decodable choices on this series: step through sizes 200/300/400/600 to match the port and flow band your line needs; choose a manual drain (as fitted here) for operator-emptied bowls, an automatic drain for unattended condensate removal, or the differential-pressure default; select 40 um standard or 5 um (W) filtration; pick the embedded square gauge or an external round gauge with MPa, psi or bar scale; order PT, G (BSPP) or NPT threads; and include or omit the bracket. This unit is the low-pressure regulator type - its exact regulation range is not published in the sheet we work from, so confirm it with us. Flow is published as curves, not a single rating, so ask us to check sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR30015MLC1T AirTAC Filter Regulator 1/2 in NPT FAQ

AirTAC publishes flow for the GFR series as curves, not a single rated figure, so we do not quote a number here. Tell us your line's flow and pressure demand and we will confirm the sizing from the datasheet before you order.

This unit's bowl is fitted with a manual drain: condensate is released by an operator, which suits installations with regular maintenance rounds. If the point of use is unattended, ask about the automatic drain option; the series default is a differential-pressure drain.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR30015MLC1T AirTAC Filter Regulator 1/2 in NPT

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR30015MLC1T and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.