The AirTAC GFR300C08LJC3T AirTAC Filter Regulator 1/4 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR300C08LJC3T is a GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is built for 1/4 in NPT ports, carries the 40 um standard filter element, and uses the differential-pressure drain. It is the low-pressure regulator type (code L), a round gauge scaled in bar is fitted, and no mounting bracket is included (code J).
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, and options including manual or automatic drains, a 5 um (W) element, G or NPT threads, gauge styles and scales, and bracket choices. Max inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm sizing figures from the datasheet for your application.
| Model | GFR300C08LJC3T AirTAC Filter Regulator 1/4 in NPT |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C0 (two-unit set) |
Filter the shop air and hold a steady low pressure to clamping cylinders on a CNC fixture, keeping part hold-down consistent through every cycle.
Conditions the air feeding carton-sealing and wrapping heads on a packaging line, with the fitted round bar gauge giving operators a local pressure readout.
Regulate atomizing air at low settings on a coating or spray station while the 40 um element keeps water and debris out of the nozzle circuit.
Size and port come first: GFR300 serves 1/4 in lines, and stepping up to GFR400 or GFR600 buys more passage for higher air demand - match the size to the circuit. Drain choice matters where condensate is heavy: this unit uses the differential-pressure drain (the default); automatic (A) and manual (M) drains are orderable alternatives. Element grade is the 40 um standard here; specify W for the 5 um option where finer filtration is needed. Thread: this version is NPT; PT is the standard thread and G is also a catalogue option. This is the low-pressure type (L) with a round bar gauge fitted and no bracket. Because flow is published as curves rather than a single rated figure, send us your application details and we will confirm sizing from the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Send us your line size and air demand and we will confirm the sizing from the datasheet on request.
The L in the code marks the low-pressure regulator type rather than the standard type. Its exact adjustment range is not published in our sheet, so we do not state a figure; ask us and we will confirm the range from the datasheet before you order.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.