verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR400-10 AirTAC Filter Regulator, NPT 3/8 in, 5 um

The AirTAC GFR400-10 AirTAC Filter Regulator, NPT 3/8 in, 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT3/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT3/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$73.89 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR400-10 AirTAC Filter Regulator, NPT 3/8 in, 5 um

The AirTAC GFR400-10 is a size 400 filter regulator: it removes water and particulate from compressed air and sets downstream pressure in a single body. This configuration is threaded 3/8 in NPT, carries the fine 5 um filter element (code W) for cleaner air than the standard 40 um grade, drains collected condensate by hand via the manual drain, and includes a reverse/check valve (code K). Outlet pressure is set across the 0.05-0.9 MPa (7-130 psi) range that applies to the manual-drain version, read on the fitted round gauge with MPa scale. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). The polycarbonate bowl suits the 400 size; only the 600 size uses an aluminium alloy bowl. No mounting bracket is fitted (code J).

This is a genuine AirTAC part. The GFR filter-regulator line is published in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of PT (standard), G or NPT thread, differential-pressure, automatic or manual drains, 40 um or 5 um filtration, gauge style and scale options, and an optional low-pressure regulator type. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing figures for your application on request.

GFR400-10 AirTAC Filter Regulator, NPT 3/8 in, 5 um Technical Specifications

ModelGFR400-10 AirTAC Filter Regulator, NPT 3/8 in, 5 um
SeriesGFR400 filter regulator
Port sizePT3/8" (NPT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR400-10 AirTAC Filter Regulator, NPT 3/8 in, 5 um

GFR400G-series filter regulator, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · PT3/8" · 5 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-10 (two-unit set)

Where the GFR400-10 AirTAC Filter Regulator, NPT 3/8 in, 5 um Is Used

precision_manufacturing

CNC machine tool air supply

Point-of-use conditioning for a machining centre's pneumatic valves and actuators: the 5 um element keeps fine contaminants out of the control circuit while the regulator sets a stable working pressure for tool clamping and tool-change cylinders.

conveyor_belt

Packaging line conveyor diverters

Feeding the air cylinders that push, divert and stop product on a packaging conveyor: the GFR400-10 filters the shop air to 5 um and holds the set pressure the diverter cylinders were sized for, with the manual drain emptied during shift checks.

science

Laboratory sample-prep bench

Clean, regulated air for a lab bench running pneumatic sample handlers and small process instruments: the 5 um grade and reverse/check valve protect sensitive downstream devices, and the MPa gauge lets technicians verify the set point at a glance.

Is the GFR400-10 AirTAC Filter Regulator, NPT 3/8 in, 5 um the Right Unit?

Size 400 with a 3/8 in port sits in the middle of the GFR range: step up to 600 or down to 300/200 depending on the flow your line needs - we confirm the published flow curves against your demand before you order. This unit already carries the fine 5 um element (W); the standard grade is 40 um if your application does not need the finer filtration. Manual drain (M) means an operator drains the bowl by hand - choose automatic or the differential-pressure default if nobody is at the machine regularly. The fitted round gauge reads in MPa; psi and bar scales and an embedded square gauge are the other catalogue options. Thread here is NPT; PT is the standard and G is also available to order. Bracket: none fitted (J). Then the honest routing: because flow is published as curves, not a single rating, ask us to confirm sizing against the application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR400-10 AirTAC Filter Regulator, NPT 3/8 in, 5 um FAQ

AirTAC publishes flow for the GFR400 series as curves, not as a single rated number, so we do not quote a figure that is not in the datasheet. Tell us your line pressure and the air demand of your equipment and we will confirm the flow and sizing figures from the datasheet on request before you order.

The M code means condensate collected in the polycarbonate bowl is drained by hand, so the unit suits installations that are checked on a regular schedule; automatic or differential-pressure drains are the catalogue alternatives where unattended operation matters. The W code fits the 5 um element instead of the 40 um standard, which is the right choice when downstream valves, cylinders or instruments need cleaner air.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR400-10 AirTAC Filter Regulator, NPT 3/8 in, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR40010MJC1WTK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.