The AirTAC GFR400-10MC3WT AirTAC Filter Regulator NPT3/8, 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT3/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR400-10MC3WT is a filter regulator: it removes water and particulate from compressed air and holds downstream pressure steady in a single body. This size 400 unit is threaded NPT3/8, carries a 5 um filter element, a manual drain on a polycarbonate bowl, and a round gauge scaled in bar, with a standard regulator covering 0.05-0.9 MPa (7-130 psi) and a maximum inlet pressure of 1.0 MPa (145 psi) at -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR series spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, and options for drain type, filter grade, gauge style and scale, thread (PT standard; G and NPT to order) and bracket. Flow is published as curves rather than a single rating, so ask us to confirm datasheet figures for your application.
| Model | GFR400-10MC3WT AirTAC Filter Regulator NPT3/8, 5 um |
|---|---|
| Series | GFR400 filter regulator |
| Port size | PT3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, bar scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 3 | Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · PT3/8" · 5 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-10 (two-unit set) |
Point-of-use water and particle removal plus a set working pressure for air tools and pneumatic screwdrivers at assembly stations, with the manual drain emptied during shift checks.
Feeding a pneumatic press or clamp cylinder from a filtered, regulated supply so the die or workpiece holding pressure stays where the operator sets it.
Supplying filtered, regulated air to solenoid valves and actuator pilots, where the 5 um element helps keep small orifices clear of particles and water carryover.
The decodable choices are size and port (200/300/400/600, stepping up as your flow demand grows), drain type (manual here; automatic and differential-pressure variants are available), filter grade (5 um fitted; 40 um is the standard element), gauge style and scale (round bar gauge fitted; embedded square gauges in MPa, psi or bar are standard), thread (PT is the standard; G and NPT are order options) and bracket (included on this unit). AirTAC publishes flow as curves, not a single rated figure, so send us your flow and pressure requirements and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes G-series flow as curves, not as a single rated figure, so we do not quote a rated flow number. Tell us your downstream flow demand and working pressure, and we will confirm from the datasheet whether this size 400, NPT3/8 unit is correctly sized for the application.
You open the bowl drain periodically to discharge collected water and contaminants. If you would rather not do this, the same unit can be ordered with an automatic or differential-pressure drain; note that the regulation range for those drain types is 0.15-0.9 MPa (20-130 psi), while this manual-drain unit covers 0.05-0.9 MPa (7-130 psi).