verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR400-15LJC2TK AirTAC Filter Regulator NPT1/2 Low-Pressure

The AirTAC GFR400-15LJC2TK AirTAC Filter Regulator NPT1/2 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/2" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$73.85 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR400-15LJC2TK AirTAC Filter Regulator NPT1/2 Low-Pressure

The GFR400-15LJC2TK is an AirTAC GFR400 filter regulator: water and particulate filtration plus pressure regulation combined in a single body. This size 400 unit is built around a 1/2 in NPT port and carries the low-pressure regulator type (code L), so it is the version to specify when the downstream circuit must be held at reduced working pressure rather than near line pressure. The 40 um standard filter element handles everyday water and particle removal, the differential-pressure drain bleeds collected condensate automatically as flow passes through, and the fitted check valve (code K) holds the downstream setting if upstream supply is interrupted. The round gauge supplied is scaled in psi, and the polycarbonate bowl lets you see the condensate level at a glance.

This is a genuine AirTAC part. The GFR family is published in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, and options across the line include 5 um filtration (code W), automatic or manual drains, G (BSPP) or NPT threads in place of the PT standard, gauge choices and scale variants. Flow figures for this series are published as curves rather than a single rating, so ask us and we will confirm the datasheet figures for your application on request.

GFR400-15LJC2TK AirTAC Filter Regulator NPT1/2 Low-Pressure Technical Specifications

ModelGFR400-15LJC2TK AirTAC Filter Regulator NPT1/2 Low-Pressure
SeriesGFR400 filter regulator
Port sizePT1/2" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR400-15LJC2TK AirTAC Filter Regulator NPT1/2 Low-Pressure

GFR400G-series filter regulator, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · PT1/2" · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-15 (two-unit set)

Where the GFR400-15LJC2TK AirTAC Filter Regulator NPT1/2 Low-Pressure Is Used

factory

Low-pressure supply to a packaging machine's film-sealing circuit

Film sealing jaws and clamping cylinders on a packaging line need a steady, reduced pressure well below the main header. This low-pressure-type filter regulator, fed from the plant 1/2 in air main, cleans the air and lets the operator set and read the sealing pressure in psi, with the check valve holding the setting through brief supply dips.

settings_input_component

Point-of-use conditioning for a pneumatic panel on a bottling line

Air cylinders, grippers and gate actuators on a bottling conveyor are fed from a local pneumatic panel. Mounted at the panel inlet on a 1/2 in drop, this unit removes water and pipe-scale particles at 40 um, regulates the panel pressure down from the header, and its differential-pressure drain keeps condensate out of the valves without daily attention.

science

Regulated air to laboratory and test-bench instrumentation

Test benches and lab rigs running pneumatic instruments need clean, low, stable pressure from a shop-air supply. Connected to a 1/2 in bench line, this filter regulator strips water and particulate before the instruments, holds the low test pressure the rig requires, and the psi round gauge gives the operator a direct pressure readout.

Is the GFR400-15LJC2TK AirTAC Filter Regulator NPT1/2 Low-Pressure the Right Unit?

Start with the port step: this unit is the size 400, 1/2 in version, the right choice when your air main and downstream consumers are on 1/2 in lines and the flow demand sits in that size band - step up to size 600 or down to size 300 if your piping differs. The drain is the differential-pressure type, which needs no operator attention; if your machine is shut down for long periods or you want positive control, the automatic (A) and manual (M) drain variants are decodable alternatives. Filtration is the 40 um standard element; specify the W code if the 5 um element is required. The gauge here is the external round type scaled in psi; embedded square gauges and MPa or bar scales are the other catalogue choices. Thread is NPT on this unit, with G (BSPP) orderable, and note that the J code means no mounting bracket is supplied - order the bracket variant if you panel- or wall-mount the unit.

One honest routing note: AirTAC publishes flow for this series as curves, not as a single rated figure, so we do not quote a flow number here. Send us your application details and we will confirm the sizing against the datasheet curves before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR400-15LJC2TK AirTAC Filter Regulator NPT1/2 Low-Pressure FAQ

AirTAC publishes flow for the G-series as curves, not as a single rated figure, so we do not quote a flow number for this unit. Tell us your application - line pressure, required downstream pressure and the consumers you are feeding - and we will confirm the relevant datasheet flow curve and help you check whether the size 400, 1/2 in port is the right step before you order.

The L is the low-pressure regulator type. It is the version intended for circuits that must run at reduced working pressure rather than near line pressure. The exact adjustment range for the low-pressure type is not published in the material we hold, so we confirm it on request; the standard-type GFR units adjust from 0.15 to 0.9 MPa (20-130 psi) with the differential-pressure drain fitted, which this unit carries.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR400-15LJC2TK AirTAC Filter Regulator NPT1/2 Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR40015LJC2TK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.