AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR40010AJC2G AirTAC Filter Regulator G3/8, Auto Drain

The AirTAC GFR40010AJC2G AirTAC Filter Regulator G3/8, Auto Drain is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT3/8" ports, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$72.85 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR40010AJC2G AirTAC Filter Regulator G3/8, Auto Drain

The AirTAC GFR40010AJC2G is a GFR400-series filter regulator: it removes water and particulate from compressed air and holds downstream pressure steady in a single compact body. This configuration is built around a G3/8 (BSPP) port in the size-400 frame, with an automatic drain that ejects collected condensate from the polycarbonate bowl without anyone having to open it - a good fit for points of use that are not checked daily. The 40 um standard element handles general-purpose air preparation, and the fitted round gauge reads outlet pressure in psi so operators can verify settings at a glance. The standard regulator covers an adjustment range of 0.15-0.9 MPa (20-130 psi), with a maximum inlet pressure of 1.0 MPa (145 psi), and the unit operates from -5 to 70 C in non-freezing conditions.

This is a genuine AirTAC part. The GFR filter-regulator family spans sizes 200, 300, 400 and 600, with port options from 1/8 in to 1 in, PT as the standard thread and G or NPT available to order, a choice of differential-pressure, automatic or manual drain, an optional 5 um (code W) element, square or round gauges with MPa, psi or bar scales, and bracket options. Rated flow for this series is published as curves rather than a single figure, so ask us to confirm the datasheet figures for your application before ordering.

GFR40010AJC2G AirTAC Filter Regulator G3/8, Auto Drain Technical Specifications

ModelGFR40010AJC2G AirTAC Filter Regulator G3/8, Auto Drain
SeriesGFR400 filter regulator
Port sizePT3/8" (G (BSPP) thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR40010AJC2G AirTAC Filter Regulator G3/8, Auto Drain

GFR400G-series filter regulator, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · PT3/8" · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-10 (two-unit set)

Where the GFR40010AJC2G AirTAC Filter Regulator G3/8, Auto Drain Is Used

precision_manufacturing

CNC machining cell air drops

Point-of-use preparation at a machining centre: the automatic drain keeps condensate out of the supply to spindle-clamp and tool-change actuators, while the regulator holds a steady setting on the psi gauge through the shift.

conveyor_belt

Packaging line cylinder supply

Feeding pneumatic cylinders and diverters on a bottling or cartoning conveyor: the 40 um element stops pipe scale and water reaching the valves, and the regulator pins actuator pressure so stops and pushes stay repeatable.

science

Lab automation pick-and-place skid

Supplying a compact gripper and vacuum-ejector skid in a laboratory or small-batch assembly setting: the G3/8 filter regulator conditions the air at the frame, and the automatic drain suits equipment that runs unattended.

Is the GFR40010AJC2G AirTAC Filter Regulator G3/8, Auto Drain the Right Unit?

Start with the size and port: GFR comes in sizes 200, 300, 400 and 600, stepping up in port and flow capacity, and this unit sits at size 400 with a G3/8 port - match the step to the air demand of the circuit it feeds, and we will confirm the flow curves against your requirement. Next choose the drain: automatic (fitted here) suits unattended or hard-to-reach installations, manual suits routinely attended points, and differential-pressure draining is the catalogue default. Filter grade is 40 um as standard; specify the W code for 5 um where finer particulate capture matters. Gauge choices are the embedded square gauge or an external round gauge (this unit carries the round type) in MPa, psi or bar scales - psi is fitted here. Thread is PT as standard with G (BSPP) and NPT as order options; this unit is built with G. Bracket inclusion is optional - this configuration is supplied without a bracket. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR40010AJC2G AirTAC Filter Regulator G3/8, Auto Drain FAQ

AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so there is no one l/min or SCFM number we can honestly quote. Send us your air demand and line conditions and we will confirm the sizing from the datasheet curves on request before you order.

The A in the code GFR40010AJC2G specifies an automatic drain: condensate collected in the polycarbonate bowl is ejected on its own, which suits installations that are not checked daily. The catalogue alternatives are a manual drain, where an operator opens the bowl drain, and the differential-pressure drain, which is the default when no drain code is given. The regulation range for automatic and differential-pressure drains is 0.15-0.9 MPa (20-130 psi).

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR40010AJC2G AirTAC Filter Regulator G3/8, Auto Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR40010AJC2G and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.