verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR40010AJF2WGK AirTAC Filter Regulator G3/8, 5 um

The AirTAC GFR40010AJF2WGK AirTAC Filter Regulator G3/8, 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT3/8" ports, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$84.22 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR40010AJF2WGK AirTAC Filter Regulator G3/8, 5 um

The AirTAC GFR40010AJF2WGK is a GFR-series filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This 400-size unit is configured with a G3/8 (BSPP) port, a 5 um filter element for finer filtration than the standard 40 um grade, an automatic drain that expels collected condensate without manual attention, an embedded square gauge reading in psi, and a built-in reverse (check) valve. The standard regulator covers an adjustment range of 0.15-0.9 MPa (20-130 psi), with a maximum inlet pressure of 1.0 MPa (145 psi). Operating temperature is -5 to 70 C (non-freezing), and the polycarbonate bowl suits the 400 size.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port options from 1/8 to 1 inch, a choice of 40 um or 5 um filtration, differential-pressure, automatic or manual drains, gauge and scale options, PT, G or NPT threads, and optional reverse valves. Flow is published as curves rather than a single rating, so ask us to confirm sizing and datasheet figures for your application before ordering.

GFR40010AJF2WGK AirTAC Filter Regulator G3/8, 5 um Technical Specifications

ModelGFR40010AJF2WGK AirTAC Filter Regulator G3/8, 5 um
SeriesGFR400 filter regulator
Port sizePT3/8" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR40010AJF2WGK AirTAC Filter Regulator G3/8, 5 um

GFR400G-series filter regulator, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · PT3/8" · 5 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-10 (two-unit set)

Where the GFR40010AJF2WGK AirTAC Filter Regulator G3/8, 5 um Is Used

precision_manufacturing

CNC machine pneumatic clamping

Feeding clamping cylinders and vise actuators on a machining centre, where the 5 um element protects precision valves and the regulator holds a steady clamp pressure read locally in psi.

conveyor_belt

Packaging conveyor actuator supply

Conditioning and regulating air to conveyor stopper and pusher cylinders on a packaging line, with the automatic drain keeping condensate off the actuators during continuous shifts.

factory

Assembly press air preparation

A point-of-use filter regulator ahead of a light assembly press or riveting station, where the check valve holds downstream pressure if supply is interrupted and the psi gauge aids setup.

Is the GFR40010AJF2WGK AirTAC Filter Regulator G3/8, 5 um the Right Unit?

Choose the 400 size with its G3/8 port when your line calls for a mid-to-large port step; larger sizes carry larger ports and higher flow capacity, and we will confirm the exact curve against your demand. This unit's 5 um element (code W) suits applications needing finer particulate capture than the 40 um standard; the automatic drain is the right choice where bowls are hard to reach or condensate loads are continuous. The square gauge reads in psi; MPa and bar scales and an external round gauge are alternatives. Thread here is G (BSPP); PT is the standard offering and NPT is an order option. Note this configuration ships without a mounting bracket (code J).

Because flow is published as curves rather than a single rated figure, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR40010AJF2WGK AirTAC Filter Regulator G3/8, 5 um FAQ

AirTAC publishes flow for the GFR400 series as curves, not as a single rated number, so we do not quote a figure that could mislead. Send us your application's flow and pressure requirements and we will confirm the correct sizing from the datasheet on request.

The W in the code sets the 5 um filter grade, one grade finer than the 40 um standard, for better protection of downstream components. The A sets an automatic drain, which expels collected condensate on its own instead of the default differential-pressure drain, useful where the unit is mounted in a hard-to-reach spot. Both are standard catalogue options for this family.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR40010AJF2WGK AirTAC Filter Regulator G3/8, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR40010AJF2WGK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.