verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR40010ALJC2 AirTAC Filter Regulator PT3/8, Low-Pressure

The AirTAC GFR40010ALJC2 AirTAC Filter Regulator PT3/8, Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT3/8" ports, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$72.62 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR40010ALJC2 AirTAC Filter Regulator PT3/8, Low-Pressure

The AirTAC GFR400 series combines water and particulate filtration with pressure regulation in a single body, so one 3/8 in (PT3/8) unit both cleans the compressed air and sets the downstream working pressure. This configuration, GFR40010ALJC2, is the low-pressure regulator type with a 40 um standard filter element, an automatic drain that expels collected condensate without manual attention, a round external gauge reading in psi, no reverse/check valve, and no mounting bracket. The polycarbonate bowl lets you see the condensate level at a glance; maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part from the G-series air-treatment line, which spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drains, a 5 um (code W) element option, gauge style and scale choices, and PT, G (BSPP) or NPT threads. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering.

GFR40010ALJC2 AirTAC Filter Regulator PT3/8, Low-Pressure Technical Specifications

ModelGFR40010ALJC2 AirTAC Filter Regulator PT3/8, Low-Pressure
SeriesGFR400 filter regulator
Port sizePT3/8" (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR40010ALJC2 AirTAC Filter Regulator PT3/8, Low-Pressure

GFR400G-series filter regulator, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · PT3/8" · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-10 (two-unit set)

Where the GFR40010ALJC2 AirTAC Filter Regulator PT3/8, Low-Pressure Is Used

valve

Pneumatic press circuits on packaging lines

On a carton-closing or blister press fed from the plant main, this 3/8 in filter regulator cleans the supply and holds the working pressure at the low setting the press cylinder needs, while the automatic drain keeps condensate out of the valve stack below.

precision_manufacturing

Air preparation for textile machinery

Looms and knitting machines run many small air jets and cylinders from a shared 3/8 in drop; a low-pressure filter regulator at each machine protects the delicate jet components from water and scale and keeps the regulated pressure steady through the shift.

settings_input_component

Pick-and-place cells with low-pressure actuation

In an assembly cell where grippers and small actuators are deliberately run at reduced pressure to protect delicate parts, this unit filters the incoming air, regulates it down to the low working band, and shows the setpoint on the round psi gauge at the panel.

Is the GFR40010ALJC2 AirTAC Filter Regulator PT3/8, Low-Pressure the Right Unit?

Start with the port step: GFR400 carries PT3/8 ports, so match it to the 3/8 in air line feeding your machine - if your flow demand points to a neighbouring size, the 200/300/400/600 range lets you step up or down. Because this unit is the low-pressure regulator type, it suits circuits held below the standard regulated band; the exact adjustment range for the low-pressure type is not published in the sheet we work from, so confirm it with us against your setpoint. The automatic drain is the right choice where the unit sits in an awkward or unattended position; choose manual where you prefer a controlled, periodic blow-down, or differential-pressure where you want draining tied to the pressure drop across the element. The 40 um element is the standard grade for general plant air; specify the 5 um (W) option only where finer filtration is genuinely needed. The round psi gauge is fitted as coded, and PT is the standard thread - G (BSPP) and NPT are order options. A bracket is not included with this code, so plan the mounting accordingly. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR40010ALJC2 AirTAC Filter Regulator PT3/8, Low-Pressure FAQ

AirTAC publishes flow for the GFR400 series as curves, not as a single rated figure, so we do not quote a number here. Tell us your line pressure, downstream demand and acceptable pressure drop, and we will confirm the flow data from the datasheet for this exact 3/8 in unit before you order.

The A in the code sets the automatic drain: the bowl expels collected condensate on its own as conditions allow, so the unit suits positions that are hard to reach or left unattended. If you would rather control draining yourself, the same series is available with a manual drain, and the catalogue default is a differential-pressure drain - each is a separate order code.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR40010ALJC2 AirTAC Filter Regulator PT3/8, Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR40010ALJC2 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.