AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR40010LJC3WTK AirTAC Filter Regulator NPT3/8, 5 um

The AirTAC GFR40010LJC3WTK AirTAC Filter Regulator NPT3/8, 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT3/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadNPT
$74.17 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR40010LJC3WTK AirTAC Filter Regulator NPT3/8, 5 um

The AirTAC GFR40010LJC3WTK is a size 400 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is built for low-pressure circuits, with a fine 5 um filter element (code W), a differential-pressure drain that bleeds collected condensate automatically as flow passes through, and a reverse/check valve fitted to hold downstream pressure when the supply is interrupted. The external round gauge is scaled in bar, the 3/8 in port is NPT thread, and the unit is supplied without a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. The polycarbonate bowl lets you see the condensate level at a glance.

This is a genuine AirTAC part. The GFR family is available in sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 in, and with choices of drain type, filter grade, gauge style and scale, thread (PT standard; G and NPT as order options), bracket and reverse valve. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing figures for your application before ordering.

GFR40010LJC3WTK AirTAC Filter Regulator NPT3/8, 5 um Technical Specifications

ModelGFR40010LJC3WTK AirTAC Filter Regulator NPT3/8, 5 um
SeriesGFR400 filter regulator
Port sizePT3/8" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, bar scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR40010LJC3WTK AirTAC Filter Regulator NPT3/8, 5 um

GFR400G-series filter regulator, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
3Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · PT3/8" · 5 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-10 (two-unit set)

Where the GFR40010LJC3WTK AirTAC Filter Regulator NPT3/8, 5 um Is Used

precision_manufacturing

Low-pressure pneumatic clamping on assembly fixtures

Fixture clamps and swing cylinders on an assembly cell that are specified to run at reduced pressure get both clean, dried air from the 5 um element and a stable low-pressure setting from the low-pressure regulator, with the check valve holding the clamp position if supply drops.

conveyor_belt

Packaging and cartoning machine actuator supply

Pick-and-place and carton-closing cylinders on a packaging line take their air through this unit: water and fine dirt are stripped out before they reach the valve seals, and the differential-pressure drain keeps condensate off the machine floor without operator attention.

science

Bench-scale pilot rig and test-stand air supply

A laboratory pilot plant or component test stand running pneumatic instruments at low pressure uses this filter regulator to condition the shop-air feed, with the bar-scaled round gauge giving a clear local reading at the bench.

Is the GFR40010LJC3WTK AirTAC Filter Regulator NPT3/8, 5 um the Right Unit?

Size 400 with a 3/8 in port sits in the upper-middle of the GFR range: step up to size 600 or down to 300 depending on the flow your line needs - we will confirm the flow curve against your demand. This unit is the low-pressure type (code L), intended where downstream settings sit below the standard regulator range; because the exact adjustment range for the low-pressure type is not published in the sheet we work from, ask us to confirm it. The 5 um element (W) suits finer air-quality needs than the standard 40 um; the differential-pressure drain needs no manual attention but the bowl must not freeze. The round gauge here reads in bar (scale 3); embedded square gauges and MPa/psi scales are alternatives. NPT is the thread on this code - PT is the catalogue standard and G is also orderable. No bracket is included (code J), so plan your own mounting. We confirm all flow and datasheet figures on request before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR40010LJC3WTK AirTAC Filter Regulator NPT3/8, 5 um FAQ

AirTAC publishes flow for the GFR series as curves, not as a single rated number, so we do not quote a l/min or SCFM figure here. Send us your line pressure and required downstream flow and we will confirm the sizing from the datasheet on request before you order.

In the code GFR40010LJC3WTK, C3 selects the optional external round gauge with a bar scale (an embedded square gauge with MPa/psi/bar scales is the standard alternative), and K specifies a reverse/check valve fitted, which holds downstream pressure if the upstream supply is lost. The L code marks it as the low-pressure regulator type - ask us to confirm its adjustment range, and note that J means no mounting bracket is included.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR40010LJC3WTK AirTAC Filter Regulator NPT3/8, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR40010LJC3WTK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.