verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR40010MLC2 AirTAC Filter Regulator 3/8" PT Low-Pressure

The AirTAC GFR40010MLC2 AirTAC Filter Regulator 3/8" PT Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT3/8" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT3/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$63.32 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR40010MLC2 AirTAC Filter Regulator 3/8" PT Low-Pressure

The AirTAC GFR40010MLC2 is a filter regulator: one body that removes water and particulate from compressed air and then regulates downstream pressure. This size 400 unit is threaded PT3/8 (3/8 in, PT standard), filters to the standard 40 um grade, and drains via a manual drain valve you open by hand. It is the low-pressure (L) regulator type for applications needing lower set pressures, and it carries a round external gauge scaled in psi so operators can read and adjust the set point directly. The polycarbonate bowl is fitted with a mounting bracket included.

This is a genuine AirTAC part from the GFR400 series, one of four sizes (200, 300, 400, 600) that step up in port size and flow capacity. Across the range you can order 5 um filtration (code W), automatic or differential-pressure draining instead of manual, square embedded or round external gauges in MPa, psi or bar scales, G or NPT threads instead of PT, and a no-bracket variant. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application.

GFR40010MLC2 AirTAC Filter Regulator 3/8" PT Low-Pressure Technical Specifications

ModelGFR40010MLC2 AirTAC Filter Regulator 3/8" PT Low-Pressure
SeriesGFR400 filter regulator
Port sizePT3/8" (PT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR40010MLC2 AirTAC Filter Regulator 3/8" PT Low-Pressure

GFR400G-series filter regulator, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · PT3/8" · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-10 (two-unit set)

Where the GFR40010MLC2 AirTAC Filter Regulator 3/8" PT Low-Pressure Is Used

settings_input_component

Packaging machine air preparation

Filtering and regulating the supply to a carton-sealing line's pneumatic cylinders and grippers, with the psi gauge letting line staff verify the set point at a glance and the manual drain emptied during shift checks.

science

Low-pressure coating and spray line

Conditioning air for a paint or coating booth where atomisation needs a lower regulated pressure; the low-pressure regulator type and 40 um filtration keep particulate and water out of the finish.

handyman

Assembly bench air drop

Feeding air tools and torque drivers at a workshop bench from a 3/8 in drop line, with the bracket mounting the unit to the frame and the manual drain bled off at the end of each day.

Is the GFR40010MLC2 AirTAC Filter Regulator 3/8" PT Low-Pressure the Right Unit?

Start with the port step: this unit is 3/8 in PT, and the GFR series steps 1/8, 1/4, 3/8, 1/2, 3/4 and 1 in across sizes 200 to 600, so pick the size whose flow curve covers your demand. Drain type is a real choice: manual (this unit, lowest maintenance cost, needs someone to open the drain), automatic (drains itself), or differential-pressure (default, drains on a pressure drop). Filtration grade is 40 um standard or 5 um with code W if downstream equipment needs finer air. The gauge is an embedded square unit as standard, with this round external psi gauge as the ordered option; MPa and bar scales are also available. Thread is PT as standard, with G (BSPP) and NPT as order options, and the bracket can be omitted with code J. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR40010MLC2 AirTAC Filter Regulator 3/8" PT Low-Pressure FAQ

AirTAC publishes flow for this series as curves, not as a single rated figure, so we do not quote a number that is not in the datasheet. Tell us your application and we will confirm the flow figures and check the sizing against the curve for you before you order.

The M in the code specifies a manual drain: someone opens the valve to empty collected water. If you prefer the bowl to look after itself, the same GFR400 body is available with an automatic drain (code A) or the differential-pressure drain that is the series default; the regulator adjustment range also differs by drain type, and for this low-pressure (L) version we confirm the exact set range from the datasheet on request.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR40010MLC2 AirTAC Filter Regulator 3/8" PT Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR40010MLC2 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.