The AirTAC GFR40010NT AirTAC Filter Regulator, NPT 3/8 in is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT3/8" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR40010NT is a size 400 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration has a 3/8 in NPT port, the standard 40 um filter element, and a differential-pressure drain that bleeds collected condensate automatically whenever the pressure drop across the element is high enough. No gauge is fitted (code N), so add your own if a visual setting reference is needed. The polycarbonate bowl suits this size, and a mounting bracket is included.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, optional 5 um filtration (code W), automatic or manual drains, and G or NPT thread options. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application on request.
| Model | GFR40010NT AirTAC Filter Regulator, NPT 3/8 in |
|---|---|
| Series | GFR400 filter regulator |
| Port size | PT3/8" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Not fitted |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| 10 | Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · PT3/8" · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-10 (two-unit set) |
Clean, regulated air feeding a bank of directional control valves on an automated machine, keeping spool operation consistent as plant pressure fluctuates.
Conditioned air for the cylinders and air chutes that divert cartons on packaging and distribution lines, with condensate bled off automatically between shifts.
A point-of-use filter regulator at a machine drop in a factory air ring main, protecting downstream tools and actuators from water and pipe scale.
Step up or down through the GFR sizes (200/300/400/600) to match the port and flow path your line needs; this unit sits at the 3/8 in NPT level. Choose the drain to suit maintenance access: differential-pressure (as fitted here) for hands-off condensate bleeding, automatic for continuous discharge, or manual where you want controlled draining. The standard element is 40 um; specify W for 5 um when finer pre-filtration matters. Thread is PT as standard, with G (BSPP) and NPT as order options - this unit carries NPT. A gauge is not fitted, so plan for external indication if operators need to read the set pressure. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes G-series flow as performance curves rather than a single rated figure, so we do not quote a number here. Tell us your application and we will confirm the flow data from the datasheet on request before you order.
The trailing N in GFR40010NT means no pressure gauge is supplied. G-series units with a regulator can be ordered with an embedded square gauge or an optional external round gauge, with MPa, psi or bar scales - contact us to select the right gauge variant.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.