The AirTAC GFR40015ALF2GK AirTAC Filter Regulator G1/2 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/2" ports, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR40015ALF2GK is a size 400 filter regulator: water and particulate filtration plus pressure regulation combined in a single body. This configuration carries a G1/2 (BSPP) port, an automatic drain that expels collected condensate without manual attention, the standard 40 um filter element, and the low-pressure regulator type for circuits that run below standard line pressures. The embedded square gauge reads in psi, a reverse/check valve is fitted to hold downstream settings, and the mounting bracket is included.
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drains, 40 um or 5 um (code W) filtration, MPa, psi or bar gauge scales, and PT, G or NPT threads. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm sizing figures from the datasheet for your application.
| Model | GFR40015ALF2GK AirTAC Filter Regulator G1/2 Low-Pressure |
|---|---|
| Series | GFR400 filter regulator |
| Port size | PT1/2" (G (BSPP) thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Automatic drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2". |
| A | Drain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| G | G (BSPP) thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · PT1/2" · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-15 (two-unit set) |
Feeding clean, regulated air to carton-forming and case-sealing machinery on a packaging line, where the automatic drain keeps condensate out of the circuit without operator attention.
Supplying a low-pressure clamping or holding circuit on an assembly fixture, where the low-pressure regulator type and fitted check valve hold the set pressure downstream.
Conditioning the air feeding conveyor diverters, gate cylinders and stopper actuators, with the 40 um element protecting valve spools from water and particulate carryover.
Size 400 with a G1/2 port sits in the upper-middle of the GFR range; step up to size 600 or down to 300 depending on the flow your line needs - we will confirm the curve against your demand before you order. This unit has the automatic drain, the right choice where the bowl is mounted in a position that is awkward to reach; choose manual drain only if you prefer scheduled blowdowns. The 40 um element is the standard grade for general plant air; specify the W variant if you need 5 um. The fitted square gauge reads psi; MPa and bar scales and an external round gauge are available. Thread here is G (BSPP) - PT is the standard thread and G or NPT are order options. Bracket included. Note this is the low-pressure regulator type; its exact adjustment range is not published, so confirm it with us against your setpoint.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so no one number would be honest. Send us your line demand and we will confirm the sizing from the datasheet curves before you order.
The A in the code specifies the automatic drain, which discharges collected condensate by itself - useful where the unit is mounted out of easy reach. The GFR family is also available with a manual drain or the differential-pressure (default) drain; tell us which you need and we will decode the matching variant.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.