verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR40015ALF2WG AirTAC Filter Regulator G1/2 5 um Auto Drain

The AirTAC GFR40015ALF2WG AirTAC Filter Regulator G1/2 5 um Auto Drain is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/2" ports, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$73.97 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR40015ALF2WG AirTAC Filter Regulator G1/2 5 um Auto Drain

The AirTAC GFR40015ALF2WG is a size-400 filter regulator: water and particulate filtration plus pressure regulation combined in one body. This configuration carries a G1/2 (BSPP) port, a 5 um filter element (code W, finer than the 40 um standard), an automatic drain that vents collected condensate without manual attention, and a low-pressure regulator type for applications set below standard ranges. The embedded square gauge reads in psi, a mounting bracket is included, and the polycarbonate bowl lets you see the condensate level at a glance.

This is a genuine AirTAC part from the GFR400 series, one of four sizes (200/300/400/600) covering a range of ports and flow capacities, with options including 40 um or 5 um filtration, differential-pressure, automatic or manual drains, MPa, psi or bar gauge scales, and PT, G or NPT threads. Flow is published as curves rather than a single rated figure, so ask us to confirm flow or any datasheet figure for your application before ordering.

GFR40015ALF2WG AirTAC Filter Regulator G1/2 5 um Auto Drain Technical Specifications

ModelGFR40015ALF2WG AirTAC Filter Regulator G1/2 5 um Auto Drain
SeriesGFR400 filter regulator
Port sizePT1/2" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR40015ALF2WG AirTAC Filter Regulator G1/2 5 um Auto Drain

GFR400G-series filter regulator, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · PT1/2" · 5 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-15 (two-unit set)

Where the GFR40015ALF2WG AirTAC Filter Regulator G1/2 5 um Auto Drain Is Used

precision_manufacturing

Pneumatic clamping on CNC machining fixtures

Filtered, regulated air supplied to fixture clamps on a machining centre, where the 5 um element protects clamp valves from particulate and the low-pressure regulator holds a gentle, consistent clamp force. The automatic drain suits a cell that runs unattended between shifts.

conveyor_belt

Packaging line pick-and-place actuator supply

Conditioning the air feed to vacuum and gripper cylinders on a packaging conveyor, where the filter-regulator removes water and fines in one body and the psi gauge lets line staff verify set pressure at a glance. The included bracket mounts the unit at the line drop.

science

Laboratory test-rig air benches

Supplying clean, low-pressure regulated air to bench-top test rigs and pilot rigs in an R&D or quality lab, where the 5 um grade keeps sensitive instrumentation clean and the square psi gauge gives a clear local reading for test records.

Is the GFR40015ALF2WG AirTAC Filter Regulator G1/2 5 um Auto Drain the Right Unit?

Size 400 with a 1/2 in port suits lines whose flow demand sits in the upper mid-range; step down to 200/300 for smaller circuits or up to 600 for higher flow, since the port step is the main sizing lever. Choose the automatic drain on this model where the unit is hard to reach or the line runs unattended; manual drain suits attended, intermittent duty, and the differential-pressure default drains only when the pressure drop warrants it. The 5 um element (code W) is the right pick where downstream valves or instruments tolerate less particulate than the 40 um standard allows; note the finer element loads faster and check the drain choice accordingly. The square gauge is fitted here reading psi; MPa and bar scales and an external round gauge are alternatives. Thread is G (BSPP) as coded, with PT standard and NPT available as order options, and a bracket is included for panel or surface fixing. Flow is published as curves, not a single rating, so send us your flow and pressure requirements and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR40015ALF2WG AirTAC Filter Regulator G1/2 5 um Auto Drain FAQ

AirTAC publishes flow for the GFR400 series as curves rather than a single rated figure, so there is no one rated flow number we can honestly quote. Send us your required flow and working pressure and we will confirm the sizing from the datasheet curves on request before you order.

The A in the code GFR40015ALF2WG specifies an automatic drain, which ejects collected condensate from the bowl without anyone opening it - the right choice for unattended or hard-to-reach installations. The same series is also available with a manual drain or the differential-pressure default drain, so you can reorder in another drain type if your maintenance routine prefers it.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR40015ALF2WG AirTAC Filter Regulator G1/2 5 um Auto Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR40015ALF2WG and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.