verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR40015ALJC2G AirTAC Filter Regulator G1/2, Auto Drain

The AirTAC GFR40015ALJC2G AirTAC Filter Regulator G1/2, Auto Drain is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/2" ports, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$72.76 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR40015ALJC2G AirTAC Filter Regulator G1/2, Auto Drain

The GFR40015ALJC2G is an AirTAC GFR400 filter regulator: one body that removes water and particulate from compressed air and then regulates downstream pressure. This 1/2 in (G1/2) unit is built around a 40 um standard filter element and an automatic drain, so collected condensate is expelled from the PC bowl without anyone having to open the drain by hand. It is the low-pressure (L) type, and it comes fitted with an external round gauge scaled in psi so operators can read and set the working pressure directly. Maximum working (inlet) pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GFR family is published in sizes 200, 300, 400 and 600, with port options, drain choices (differential-pressure, automatic or manual), a 5 um (W) element option, gauge and scale choices, and thread options - PT as standard, with G and NPT available to order. Flow is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for your application on request.

GFR40015ALJC2G AirTAC Filter Regulator G1/2, Auto Drain Technical Specifications

ModelGFR40015ALJC2G AirTAC Filter Regulator G1/2, Auto Drain
SeriesGFR400 filter regulator
Port sizePT1/2" (G (BSPP) thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR40015ALJC2G AirTAC Filter Regulator G1/2, Auto Drain

GFR400G-series filter regulator, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · PT1/2" · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-15 (two-unit set)

Where the GFR40015ALJC2G AirTAC Filter Regulator G1/2, Auto Drain Is Used

valve

Pneumatic valve and actuator supply lines

Installed ahead of directional valves and cylinder circuits on automated machinery, this unit filters water and particulate out of the plant air supply and holds the downstream pressure the valve stack was set up for, with the psi gauge giving the technician a direct reading at the panel.

precision_manufacturing

Machine-tool air circuit conditioning

On CNC and special-purpose machines that run dedicated 1/2 in air drops, this filter regulator conditions the supply feeding clamps, tool-changers and air-powered fixtures, with the automatic drain keeping condensate out of the bowl during unattended shifts.

science

Test-rig and laboratory air regulation

For bench and pilot rigs that need air held at reduced, stable pressure rather than full header pressure, the low-pressure type regulator lets the operator dial the working setpoint down from the plant supply while the 40 um element keeps debris out of sensitive instruments.

Is the GFR40015ALJC2G AirTAC Filter Regulator G1/2, Auto Drain the Right Unit?

Size and port set the capacity envelope: this unit is size 400 with a 1/2 in G-thread port, the step to take when your line runs 1/2 in piping and you want the larger GFR400 body behind it. The automatic drain (code A) suits points where the unit is not checked daily; choose manual drain where an operator prefers controlled blow-down, or the differential-pressure default where drain behaviour should follow the pressure differential. The 40 um element is the standard grade; specify the W code for 5 um if finer particulate capture is needed. The fitted round gauge here is scaled in psi; embedded square gauges and MPa or bar scales are the other catalogue choices. PT is the standard thread, with G and NPT as order options, and this J-coded version omits the mounting bracket. Because flow is published as curves rather than a single rating, send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR40015ALJC2G AirTAC Filter Regulator G1/2, Auto Drain FAQ

AirTAC publishes G-series flow as performance curves, not as a single rated number, so we do not quote a rated flow, Cv or SCFM figure for this unit. What we can confirm from the catalogue is the configuration: size 400, 1/2 in (G1/2) port, 40 um element, automatic drain, low-pressure regulator type and a round psi gauge, with a maximum working (inlet) pressure of 1.0 MPa (145 psi). Send us your application details and we will confirm the datasheet flow figures and correct sizing on request before you order.

The A in the code means the drain is automatic: condensate collected in the PC bowl is expelled on its own, so the unit suits installations that are not visited daily - a manual-drain version would need someone to open the drain periodically, and the differential-pressure default drains according to the pressure differential. The L code marks this as the low-pressure regulator type, intended where the working setpoint sits below the standard range; the exact adjustment range for the low-pressure type is not published in the sheet we work from, so ask us and we will confirm it on request.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR40015ALJC2G AirTAC Filter Regulator G1/2, Auto Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR40015ALJC2G and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.