AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR40015C2WG AirTAC Filter Regulator G1/2, 5 um

The AirTAC GFR40015C2WG AirTAC Filter Regulator G1/2, 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/2" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$63.57 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR40015C2WG AirTAC Filter Regulator G1/2, 5 um

The GFR40015C2WG is an AirTAC GFR400 filter regulator: filtration and pressure regulation combined in one body, with no lubricator. It removes water and particulate from compressed air through a 5 um element (the finer of the two catalogue grades) and holds downstream pressure within a 0.15-0.9 MPa (20-130 psi) adjustment range. This configuration is sized for a 1/2 inch port with G (BSPP) thread, carries a differential-pressure drain that bleeds condensate automatically as flow passes through, and is fitted with an external round gauge reading in psi. The polycarbonate bowl suits the non-freezing -5 to 70 C operating window, and a mounting bracket is included.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, and each size can be ordered with manual or automatic drain, a 40 um or 5 um element, different gauge scales, G or NPT thread in place of the PT standard, and with or without a bracket. Flow is published as curves rather than a single rated figure, so we confirm the datasheet and sizing figures for your application on request.

GFR40015C2WG AirTAC Filter Regulator G1/2, 5 um Technical Specifications

ModelGFR40015C2WG AirTAC Filter Regulator G1/2, 5 um
SeriesGFR400 filter regulator
Port sizePT1/2" (G (BSPP) thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR40015C2WG AirTAC Filter Regulator G1/2, 5 um

GFR400G-series filter regulator, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · PT1/2" · 5 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-15 (two-unit set)

Where the GFR40015C2WG AirTAC Filter Regulator G1/2, 5 um Is Used

precision_manufacturing

CNC machining centre air supply

Feeding clean, regulated air to the tool-change clamps and pneumatic actuators on a CNC machining centre, where the 5 um element protects precision valves from particulate and the psi gauge lets setters verify clamp pressure at a glance.

factory

Packaging line drop

Conditioning the air drop that serves a carton-forming and sealing line, combining water removal and steady regulated pressure in one body so sealing cylinders cycle consistently through a full shift without a separate regulator.

conveyor_belt

Conveyor diverters and stoppers

Supplying the pop-up diverters, stoppers and gate cylinders on a distribution conveyor system, where the differential-pressure drain keeps condensate out of the loop automatically and the bracket mounts the unit beside the manifold.

Is the GFR40015C2WG AirTAC Filter Regulator G1/2, 5 um the Right Unit?

Start with the port step: this unit is the 400 size at 1/2 inch, one step up from the 300 series, so choose it when your line's flow demand sits above what a 3/8 inch unit carries - and ask us to confirm the exact flow curve before ordering, since AirTAC publishes flow as curves rather than a single rating. The 5 um element here is the finer option against the 40 um standard; pick it when downstream valves or instruments need cleaner air, accepting that the finer element loads faster. The differential-pressure drain is the default: it purges condensate using the pressure drop across the element, with no operator action, whereas manual drain needs periodic bleeding and automatic drain works on a timer-free float. The round psi gauge suits US-facing panels; square gauges and MPa or bar scales are orderable. Thread is G (BSPP) here - PT is the catalogue standard and NPT is an option, so match it to your fittings, and the included bracket simplifies panel or frame mounting.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR40015C2WG AirTAC Filter Regulator G1/2, 5 um FAQ

AirTAC publishes flow for the GFR400 series as performance curves rather than a single rated figure, so there is no one number we can honestly quote. Tell us your line's air demand and we will confirm the curve and check the sizing against your application before you order - the datasheet figures are available on request.

The W in the code GFR40015C2WG selects the 5 um filtration grade instead of the 40 um standard, giving finer protection for downstream valves and instruments. The blank drain position selects the differential-pressure drain, the catalogue default, which purges collected condensate using the pressure drop across the element with no manual bleeding. A manual (M) or automatic (A) drain can be ordered instead if your maintenance routine prefers it.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR40015C2WG AirTAC Filter Regulator G1/2, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR40015C2WG and will confirm price, stock and lead time — usually within 7-8 hours.