The AirTAC GFR40015JF1WTK AirTAC Filter Regulator NPT1/2, 5 um is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/2" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR40015JF1WTK is an AirTAC GFR400 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is the size 400 unit with a 1/2 in NPT port, the fine 5 um filter element (code W), a differential-pressure drain that bleeds collected condensate automatically whenever the pressure differential across the element is high enough, a built-in reverse/check valve, and an embedded square pressure gauge scaled in MPa. The standard regulator covers an adjustment range of 0.15-0.9 MPa (20-130 psi), and the maximum working (inlet) pressure is 1.0 MPa (145 psi). The polycarbonate bowl suits non-freezing compressed-air service from -5 to 70 C.
This is a genuine AirTAC part. The GFR filter-regulator family is available in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, a choice of differential-pressure, automatic or manual drain, 40 um standard or 5 um (W) filtration, gauge scale options, PT, G or NPT threads, and bracket or no-bracket mounting. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering.
| Model | GFR40015JF1WTK AirTAC Filter Regulator NPT1/2, 5 um |
|---|---|
| Series | GFR400 filter regulator |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · PT1/2" · 5 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-15 (two-unit set) |
Feeding filtered, regulated air to a spray-booth air supply: the 5 um element keeps water and particulate out of the finish, the square gauge lets operators set and verify line pressure at a glance, and the reverse/check valve holds the setting if upstream supply dips.
Conditioning the shop-air feed to a machining centre's pneumatic circuits: one body filters the compressed air and regulates it to the pressure the machine's valves and actuators expect, with the differential-pressure drain clearing condensate during normal running.
Supplying regulated air to the cylinders and air jets on a packaging conveyor: the filter-regulator protects downstream components from water and debris, and the 1/2 in NPT port suits the larger air demand of a size 400 line.
Size 400 with a 1/2 in port sits in the upper half of the GFR range; step up to size 600 or down to 300 depending on the flow your line needs - we will confirm sizing against the published flow curves on request. This unit ships as configured with the 5 um (W) element; the 40 um element is the standard grade if you prefer coarser, longer-interval filtration. The differential-pressure drain needs no operator action but relies on flow to purge, so choose automatic or manual drain if the unit will sit at low or intermittent flow. The square MPa gauge is fitted; psi or bar scales and an external round gauge are orderable options. NPT is the thread on this code; PT and G (BSPP) are catalogue alternatives. No mounting bracket is included with the J code.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Tell us your application and we will confirm the flow/datasheet figures for this size 400, 1/2 in unit on request before you order.
This unit's differential-pressure drain purges collected condensate automatically when the pressure drop across the 5 um element builds high enough. It suits continuously flowing lines. If the unit will run at low or intermittent flow, ask for the automatic (A) or manual (M) drain version of the same GFR400-15 configuration.