The AirTAC GFR40015LJF3TK AirTAC Filter Regulator NPT1/2 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/2" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR40015LJF3TK is a size-400 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration is the low-pressure type with a 1/2 in NPT port, a 40 um standard filter element, differential-pressure drainage from the PC bowl, an embedded square gauge scaled in bar, and a built-in reverse/check valve. No mounting bracket is fitted. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR family is available in sizes 200, 300, 400 and 600 with a choice of ports, PT/G/NPT threads, drain types, 40 um or 5 um filtration, gauge scales and low-pressure or standard regulation. Because flow is published as curves rather than a single rating, we confirm the datasheet and sizing figures for your application on request.
| Model | GFR40015LJF3TK AirTAC Filter Regulator NPT1/2 Low-Pressure |
|---|---|
| Series | GFR400 filter regulator |
| Port size | PT1/2" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — square, bar scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 3 | Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · PT1/2" · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-15 (two-unit set) |
Feeding filtered, pressure-controlled air to spray booths and coating heads, where the low-pressure regulation band and 40 um water/particulate removal suit finishing equipment.
A single filter-regulator point at the inlet of a machine's air manifold, with the bar-scaled square gauge giving operators a local setpoint readout and the check valve holding the circuit against backflow.
Conditioning the 1/2 in supply branch that runs actuators and gripper cylinders on packaging and case-erector lines, with differential-pressure drainage keeping the PC bowl emptied under flow.
Size 400 with a 1/2 in port sits in the upper half of the GFR range, so step up or down (200/300/400/600) according to the air demand of the line. This unit is the low-pressure type, so confirm the setpoint range you need with us before ordering. The 40 um element is the standard grade; specify code W for 5 um where finer filtration is required. Drainage here is differential-pressure (automatic under flow); manual (M) and automatic (A) drains are alternatives. The fitted square gauge reads in bar, with MPa and psi scales available, and an external round gauge is optional. Thread is NPT in this code; PT (standard) and G are the other order options. A bracket can be added if this J-coded, bracket-less unit needs panel support.
Flow for this family is published as curves, not a single rated figure, so send us your application details and we will confirm sizing and the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR family as curves rather than a single rated figure, so no one number can be quoted here. Send us your line pressure, downstream demand and this model code, and we will confirm the flow curve and datasheet figures for your application on request.
The L in the code marks this as the low-pressure regulator version of the GFR400 filter regulator, intended where the controlled downstream pressure sits below the standard type's range. The exact adjustment range for the low-pressure type is not published in the standard tables, so confirm your required setpoint with us and we will verify suitability from the datasheet before you order.