The AirTAC GFR400C10LJF2K AirTAC Filter Regulator PT3/8 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR400C10LJF2K is a filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This size 400 unit has a PT3/8 port, the 40 um standard filter grade and a differential-pressure drain. It is the low-pressure type, and this configuration carries an embedded square gauge reading in psi plus a reverse (check) valve; no mounting bracket is fitted. The polycarbonate bowl suits the non-freezing -5 to 70 C working range, with a maximum inlet pressure of 1.0 MPa (145 psi).
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 inch, PT thread as standard and G or NPT to order, plus a choice of drain type, 5 um (W) filtration, gauge scale and bracket. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet for your application.
| Model | GFR400C10LJF2K AirTAC Filter Regulator PT3/8 Low-Pressure |
|---|---|
| Series | GFR400 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR400 | G-series filter regulator, 400 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR400 · See datasheet · 40 µm |
|---|---|
| One size down | GFR300 |
| One size up | GFR600 |
| Add lubrication | GFC400-C1 (two-unit set) |
Feeding filtered, regulated air to the cylinders on a carton-sealing conveyor; the fitted check valve helps hold the downstream setting when the upstream supply dips.
Regulating a gentle, stable supply to pneumatic grippers on a pick-and-place cell, with 40 um filtration protecting the directional valves downstream.
Setting a low, steady regulated pressure to spray guns in a paint or coating booth, with water and particulate stripped out ahead of the gun.
Pick the size and port against the air demand of your circuit: this unit is size 400 with a 3/8 in PT port, and the family steps through 200/300/400/600 with ports from 1/8 to 1 inch. Drain type is a real choice - differential-pressure (as here), automatic (A) or manual (M) - and filter grade is 40 um standard or 5 um with code W. The gauge can be ordered with MPa, psi or bar scale, and the thread can be PT (standard), G or NPT.
Flow for this family is published as curves rather than a single rated figure, and the exact regulation range of the low-pressure type is not published on the sheet we transcribe from. Ask us to confirm sizing and the datasheet against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR family as curves, not as a single rated figure, so we do not quote a number here. Tell us your application and we will confirm the flow and full datasheet figures on request before you order.
It means a reverse (check) valve is fitted. The valve helps maintain the downstream pressure setting if the upstream supply pressure drops. Codes without the K come without this valve.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.