verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR400C15ALJF3WT AirTAC Filter Regulator NPT1/2, 5 um

The AirTAC GFR400C15ALJF3WT AirTAC Filter Regulator NPT1/2, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$79.79 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR400C15ALJF3WT AirTAC Filter Regulator NPT1/2, 5 um

The GFR400C15ALJF3WT is an AirTAC GFR400 filter regulator: filtration and pressure regulation combined in a single body. It removes water and particulate down to 5 um (the fine W grade, versus the standard 40 um) and regulates downstream pressure in a low-pressure type configuration. This unit carries 1/2 in NPT ports, an automatic drain that expels collected condensate without manual attention, an embedded square gauge scaled in bar, and no reverse/check valve. Maximum inlet pressure is 1.0 MPa (145 psi) and the operating temperature range is -5 to 70 C, non-freezing. The bowl is metal. No mounting bracket is included with the J suffix.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and options including drain type, filter grade, gauge scale, thread form (PT standard, G and NPT to order) and bracket choice. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm flow and datasheet figures for your application before ordering.

GFR400C15ALJF3WT AirTAC Filter Regulator NPT1/2, 5 um Technical Specifications

ModelGFR400C15ALJF3WT AirTAC Filter Regulator NPT1/2, 5 um
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR400C15ALJF3WT AirTAC Filter Regulator NPT1/2, 5 um

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the GFR400C15ALJF3WT AirTAC Filter Regulator NPT1/2, 5 um Is Used

precision_manufacturing

CNC machining centre air supply

Feeds filtered, regulated air to the tool-clamp and actuation circuits of a machining centre, where the 5 um element protects precision valves from particulate and the automatic drain keeps condensate off the shop floor without operator rounds.

factory

Packaging line carton-sealing station

Supplies the pneumatic cylinders and grippers on a carton-forming and sealing station, holding a steady low-pressure setting for gentle handling while the bar gauge gives operators a visible setpoint reference.

settings_input_component

Textile machine air jet circuit

Conditions the supply to air-jet and doffing circuits on textile machinery, where the automatic drain copes with continuous condensate carry-over and the compact filter-regulator body saves panel space.

Is the GFR400C15ALJF3WT AirTAC Filter Regulator NPT1/2, 5 um the Right Unit?

Size 400 with 1/2 in NPT ports suits lines with substantial air demand; step down to 300 or up to 600 if your flow requirement or existing pipework differs. The 5 um element (code W) is the finer choice where downstream valves and instruments tolerate less particulate than the 40 um standard grade allows. The automatic drain suits unattended or hard-to-reach installations; manual and differential-pressure drains are available in the family if you prefer scheduled or load-linked draining. The square gauge here reads in bar; MPa and psi scales are alternatives. NPT is the thread on this code, ordered as the T option against the PT standard; G (BSPP) is also available. No bracket is fitted with the J suffix - add one if the unit will be wall or panel mounted rather than in-line. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR400C15ALJF3WT AirTAC Filter Regulator NPT1/2, 5 um FAQ

AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a rated flow, Cv or SCFM number. Send us your application details and we will confirm the flow and datasheet figures for this exact unit on request before you order.

The A in this code specifies an automatic drain: collected condensate is expelled from the metal bowl without manual intervention, which suits unattended or hard-to-reach installations. Manual and differential-pressure drain variants exist in the family if you prefer scheduled draining or load-linked operation.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR400C15ALJF3WT AirTAC Filter Regulator NPT1/2, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C15ALJF3WT and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.