The AirTAC GFR400C15LJNWT AirTAC Filter Regulator NPT1/2 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$63.40 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR400C15LJNWT AirTAC Filter Regulator NPT1/2 Low-Pressure

The AirTAC GFR400C15LJNWT is a size 400 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration is the low-pressure regulator type with a 1/2 in NPT port, 5 um filtration (the finer of the two published grades), a differential-pressure drain that bleeds the bowl automatically as flow passes through, no gauge fitted, no mounting bracket, and a metal bowl. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GFR family is published in sizes 200, 300, 400 and 600, with port sizes from 1/8 to 1 inch, PT as the standard thread and G or NPT as order options, a choice of 40 um or 5 um filtration, differential-pressure, automatic or manual drains, gauge and bracket options, and standard or low-pressure regulator types. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet and sizing figures for your application on request.

GFR400C15LJNWT AirTAC Filter Regulator NPT1/2 Low-Pressure Technical Specifications

ModelGFR400C15LJNWT AirTAC Filter Regulator NPT1/2 Low-Pressure
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR400C15LJNWT AirTAC Filter Regulator NPT1/2 Low-Pressure

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the GFR400C15LJNWT AirTAC Filter Regulator NPT1/2 Low-Pressure Is Used

factory

Packaging machine air supply

Point-of-use clean, regulated air for the cylinders and valves on a carton-forming or wrapping line, with the 5 um element protecting directional valves from water and fine dirt carryover.

precision_manufacturing

Pneumatic clamping on machining fixtures

Filtered, regulated supply to clamping cylinders on CNC fixture panels, where the low-pressure regulator type suits circuits that hold workpieces at reduced set pressure.

settings_input_component

Textile and converting line drops

A compact filter-regulator drop feeding air jets, tension rollers and small actuators on weaving or converting equipment, with the differential-pressure drain keeping the bowl clear during continuous running.

Is the GFR400C15LJNWT AirTAC Filter Regulator NPT1/2 Low-Pressure the Right Unit?

Size 400 with a 1/2 in port is the larger mid-range step in the GFR line; step up or down (200/300/400/600) according to the flow your line needs, and confirm the match against the published flow curves before ordering. This unit carries the W code, so it filters to 5 um rather than the 40 um standard - choose 5 um where downstream valves, cylinders or instruments need cleaner air. The drain is differential-pressure, which suits steady-flow installations; an automatic or manual drain variant can be ordered if your duty cycle differs. Thread here is NPT; PT is the catalogue standard and G (BSPP) is also available. No gauge or bracket is fitted on this code, and it is the low-pressure regulator type - ask us to confirm its regulation range and the flow curves on request, as no single rated flow figure is published.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR400C15LJNWT AirTAC Filter Regulator NPT1/2 Low-Pressure FAQ

AirTAC publishes flow for the GFR series as curves, not as a single rated number, so we do not quote a l/min, m3/h or SCFM figure. Send us your application details and we will confirm the flow curve and correct size from the datasheet on request.

The W in the code selects the 5 um element instead of the 40 um standard, giving finer protection for downstream valves and instruments. The N code means no gauge is fitted on this variant; gauge options exist in the family and can be ordered on the appropriate code. Ask us to confirm details on request.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR400C15LJNWT AirTAC Filter Regulator NPT1/2 Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C15LJNWT and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.