verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR400 · Filter Regulator (filter + regulator in one body)

GFR400C15MJF2WK AirTAC Filter Regulator PT1/2, 5 um

The AirTAC GFR400C15MJF2WK AirTAC Filter Regulator PT1/2, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$80.10 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR400C15MJF2WK AirTAC Filter Regulator PT1/2, 5 um

The AirTAC GFR400C15MJF2WK is a filter regulator: it removes water and particulate from compressed air and holds downstream pressure in a single body. This 400-size unit is built for a 1/2 in PT port and carries the W-code 5 um filtration element, one step finer than the 40 um standard element. Drainage is manual - you open the drain on the metal bowl to expel collected water when it suits your maintenance routine. A square pressure gauge reading in psi is fitted, the regulator is the standard type with an adjustment range of 0.05-0.9 MPa (7-130 psi), and a reverse/check valve is included to guard against backflow. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. No mounting bracket is included with this code.

This is a genuine AirTAC part. The GFR400 sits in the mid-range of the GFR filter-regulator line, which spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, and options across drain type, filtration grade, gauge style and scale, thread, bracket and reverse valve. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before you order.

GFR400C15MJF2WK AirTAC Filter Regulator PT1/2, 5 um Technical Specifications

ModelGFR400C15MJF2WK AirTAC Filter Regulator PT1/2, 5 um
SeriesGFR400 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR400C15MJF2WK AirTAC Filter Regulator PT1/2, 5 um

GFR400G-series filter regulator, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR400 · See datasheet · 40 µm
One size downGFR300
One size upGFR600
Add lubricationGFC400-C1 (two-unit set)

Where the GFR400C15MJF2WK AirTAC Filter Regulator PT1/2, 5 um Is Used

factory

Machine-tool air supply

A point-of-use filter regulator feeding the pneumatic valves, chucks and clamps of a CNC machining centre: water and chips-carrying particulate are stripped out down to 5 um and the supply pressure is held at the setting the machine's FRL circuit was designed around, with the manual drain opened during daily checks.

conveyor_belt

Packaging line cylinder feed

Regulated, filtered air for the extend-and-retract cylinders on a carton-sealing or case-packing conveyor. The 1/2 in PT port suits the main drop leg to a section of the line, and the manual drain lets maintenance staff clear accumulated condensate at the start of each shift.

air

Spray-finishing air prep

Clean, pressure-stable air ahead of the spray guns in a paint or coating finishing line. The 5 um element catches finer particulate than the standard element before air reaches the gun, and the regulator holds a steady gun supply pressure so finish quality does not drift as the line runs.

Is the GFR400C15MJF2WK AirTAC Filter Regulator PT1/2, 5 um the Right Unit?

Pick the size and port against the air your application actually consumes: the GFR400 with its 1/2 in PT port is the larger mid-range step in the 200/300/400/600 ladder, and the right step depends on flow demand - we can check the published flow curves against your consumption before you commit. Drain type is a real choice: manual (this code) means draining the bowl by hand, while automatic and differential-pressure drains are available on other codes. Filtration here is the 5 um element (code W) versus the 40 um standard. The fitted square gauge reads psi; scales in MPa or bar and an external round gauge are order options. PT is the standard thread; G (BSPP) and NPT are catalogue options to order. A bracket is optional and not included with this code. Because flow is published as curves, not a single rating, ask us to confirm sizing against the application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR400C15MJF2WK AirTAC Filter Regulator PT1/2, 5 um FAQ

AirTAC publishes flow for this series as curves rather than a single rated figure, so we do not quote a number here. Tell us your working pressure and air consumption and we will confirm the flow and datasheet figures for this exact model on request before you order.

Manual drain (this code) means you open the drain on the bowl yourself to expel collected water - simple and well suited to units that are checked regularly. The GFR range also offers automatic and differential-pressure drains on other codes. Note the regulator adjustment range differs by drain type: manual-drain units adjust from 0.05-0.9 MPa (7-130 psi), while automatic and differential-pressure drain versions adjust from 0.15-0.9 MPa (20-130 psi).

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR400C15MJF2WK AirTAC Filter Regulator PT1/2, 5 um

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR400C15MJF2WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.