The AirTAC GFR600-20T AirTAC Filter Regulator NPT3/4 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT3/4" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR600-20T is a filter regulator: one body that removes water and particulate from compressed air and holds downstream pressure steady. This size-600 unit is threaded NPT3/4, uses the standard 40 um filter element and the differential-pressure drain, and its standard regulator adjusts from 0.15 to 0.9 MPa (20-130 psi). Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). The embedded square gauge is fitted with a psi scale, the bowl is aluminium alloy (size 600), and no mounting bracket is included with this version.
This is a genuine AirTAC part. The GFR filter-regulator family spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, and options include automatic or manual drains, a 5 um (W) filter element, G (BSPP) or NPT thread, gauge scales in MPa, psi or bar, and bracket choice. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application.
| Model | GFR600-20T AirTAC Filter Regulator NPT3/4 |
|---|---|
| Series | GFR600 filter regulator |
| Port size | PT3/4" (NPT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — square, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR600 | G-series filter regulator, 600 body — sets the port range. |
|---|---|
| 20 | Port size PT3/4". This body offers 20 = PT3/4", 25 = PT1". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| F | Gauge shape: Square. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| T | NPT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR600 · PT3/4" · 40 µm |
|---|---|
| One size down | GFR400 |
| Add lubrication | GFC600-20 (two-unit set) |
Feeding clean, pressure-stable air to spray guns and booth equipment on an automotive paint line, where water and particulate in the supply would otherwise reach the finish.
Conditioning the air feeding a directional-valve manifold on a packaging machine, so cylinders and actuators see filtered air at a set downstream pressure.
Supplying filtered and regulated air to the stopper, pusher and lift actuators along a bottling-plant conveyor, with the 3/4 in port sized for the line's main drop.
Size and port step up together with flow demand: the GFR family runs 200/300/400/600 with ports from 1/8 in to 1 in, and this unit is size 600 with NPT3/4. Drain choices are differential-pressure (default), automatic (A) or manual (M); filter grade is 40 um standard or 5 um with the W code. Gauge scales are MPa (1), psi (2) or bar (3), and thread options are PT (standard), G (BSPP) or NPT; a bracket is included unless J is ordered. Because flow is published as curves rather than a single rating, send us your application details and we will confirm sizing against the datasheet before you order.
Quick checklist
The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for this family as curves rather than a single rated figure, so we do not quote a rated flow number. Tell us your application and required flow, and we will confirm the sizing from the datasheet on request before you order.
This GFR600-20T uses the differential-pressure drain, which is the default code position for the GFR family. If you prefer an automatic drain order the A code, or a manual drain the M code; the regulation range also differs by drain type, with manual-drain versions adjusting from 0.05 to 0.9 MPa (7-130 psi).
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.