verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR600-25 AirTAC Filter Regulator PT 1 in, Manual Drain

The AirTAC GFR600-25 AirTAC Filter Regulator PT 1 in, Manual Drain is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade40 µm
  • DrainManual drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$117.44 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR600-25 AirTAC Filter Regulator PT 1 in, Manual Drain

The AirTAC GFR600-25 is a filter regulator: one body that removes water and particulate from compressed air and holds downstream pressure steady. This 600-size unit carries a PT 1 in port, the largest port step in the G-series range, so it sits on main supply lines rather than at a single drop. The M in the code gives it a manual drain, so collected condensate is released by opening the drain fitting during checks rather than automatically. Filtration is the standard 40 um element, and the F2 in the code fits the embedded square gauge scaled in psi so the set pressure is visible at the unit. The K code adds a reverse (check) valve, and J means the unit is supplied without a mounting bracket.

This is a genuine AirTAC part from the GFR600 series, the top size of a range that steps from 200 through 600 with port options from 1/8 in to 1 in and PT, G or NPT threads to order. The aluminium alloy bowl on this size is suited to the larger unit, with a maximum inlet pressure of 1.0 MPa (145 psi) and a working temperature of -5 to 70 C (non-freezing). AirTAC publishes flow for this series as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your line before ordering.

GFR600-25 AirTAC Filter Regulator PT 1 in, Manual Drain Technical Specifications

ModelGFR600-25 AirTAC Filter Regulator PT 1 in, Manual Drain
SeriesGFR600 filter regulator
Port sizePT1" (PT thread)
Filtering grade40 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialAluminium alloy
Pressure gaugeFitted — square, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR600-25 AirTAC Filter Regulator PT 1 in, Manual Drain

GFR600G-series filter regulator, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · PT1" · 40 µm
One size downGFR400
Add lubricationGFC600-25 (two-unit set)

Where the GFR600-25 AirTAC Filter Regulator PT 1 in, Manual Drain Is Used

factory

Main plant air supply header

Installed on the 1 in main line feeding a production floor, it cleans water and scale out of the header air and holds a steady regulated pressure for every branch downstream, with the psi gauge readable from the wall.

precision_manufacturing

CNC machining cell air drop

Feeding the air supply to a CNC machining cell, it filters particulate from the mill's pneumatic clamping and tool-change circuits and keeps their operating pressure constant through the shift.

conveyor_belt

Packaging line conveyor actuators

Mounted ahead of the cylinder bank on a packaging conveyor line, it supplies filtered air to the diverters and pushers and regulates the pressure so cylinder stroke timing stays repeatable.

Is the GFR600-25 AirTAC Filter Regulator PT 1 in, Manual Drain the Right Unit?

Choose the 600 size with its PT 1 in port when the supply line itself is the constraint: the larger the port step, the more air the body can pass before pressure drop becomes the limiting factor. On this unit the drain is manual, which suits installations that are inspected on a schedule; if nobody walks the line, an automatic drain (code A) or the default differential-pressure drain removes the dependence on operator checks. The 40 um grade is the standard element for general plant air; the 5 um option (code W) is there when downstream equipment needs finer protection. The square gauge here reads in psi, and MPa or bar scales are available instead if your team works in those units. Thread is PT as standard, with G (BSPP) and NPT as order options, and this configuration ships without a bracket. Because AirTAC publishes flow only as curves and not as a single rated number, send us your application details and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR600-25 AirTAC Filter Regulator PT 1 in, Manual Drain FAQ

AirTAC publishes flow for the GFR600 series as curves, not as a single rated figure, so we do not quote a number here. Tell us your line pressure and the air demand of your equipment and we will confirm the sizing from the datasheet on request.

The M in the code gives a manual drain: condensate collected in the aluminium bowl is released when an operator opens the drain during scheduled checks. It suits lines that are inspected regularly; if the unit runs unattended, ask about the automatic (A) or differential-pressure drain versions instead.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR600-25 AirTAC Filter Regulator PT 1 in, Manual Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR60025MJF2K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.