verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR600-25ALC2T AirTAC Filter Regulator NPT 1 in

The AirTAC GFR600-25ALC2T AirTAC Filter Regulator NPT 1 in is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1" ports, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadNPT
$118.11 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR600-25ALC2T AirTAC Filter Regulator NPT 1 in

The AirTAC GFR600-25ALC2T is a filter regulator: one body that removes water and particulate from compressed air and then regulates downstream pressure. This 600-size unit is configured with a 1 in NPT port, an automatic drain that expels collected condensate without manual attention, the standard 40 um filtration element, and the low-pressure regulator type for applications that work at reduced set pressures. Because it is size 600, the drain bowl is aluminium alloy. A round pressure gauge with a psi scale is fitted, a mounting bracket is included, and no reverse (check) valve is fitted.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and can be ordered with manual or differential-pressure drains, a 5 um element (code W), embedded square or external round gauges in MPa, psi or bar scales, and PT, G (BSPP) or NPT threads. Flow is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for your application on request.

GFR600-25ALC2T AirTAC Filter Regulator NPT 1 in Technical Specifications

ModelGFR600-25ALC2T AirTAC Filter Regulator NPT 1 in
SeriesGFR600 filter regulator
Port sizePT1" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialAluminium alloy
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR600-25ALC2T AirTAC Filter Regulator NPT 1 in

GFR600G-series filter regulator, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · PT1" · 40 µm
One size downGFR400
Add lubricationGFC600-25 (two-unit set)

Where the GFR600-25ALC2T AirTAC Filter Regulator NPT 1 in Is Used

factory

Automotive paint shop air prep

On a spray-booth supply line, the filter stage strips water and pipe-scale that would otherwise blemish paint finishes, while the low-pressure regulator holds a reduced, steady set pressure at the spray guns. The automatic drain keeps condensate moving out of the aluminium bowl without an operator stopping by.

conveyor_belt

Packaging line case sealers and wrappers

Case-sealing and stretch-wrapper machines run air cylinders continuously through a shift. A 1 in filter regulator at the machine drop conditions the whole supply in one unit: the 40 um element protects directional valves from particulate, and the regulated output keeps cylinder action consistent as the header pressure wanders.

science

Bottling line rinse and fill actuators

Rinse heads and fill-station actuators on a bottling line need clean, dry-ish air at a controlled, moderate pressure. This low-pressure-type filter regulator filters the supply, holds the working pressure the station was set up for, and its round psi gauge lets technicians verify the set point at a glance during changeovers.

Is the GFR600-25ALC2T AirTAC Filter Regulator NPT 1 in the Right Unit?

Step through the real choices before ordering. Size and port: 200, 300, 400 and 600 step up in port and flow capacity, so match the size to the air demand of the circuit rather than to the pipe alone; this unit is the largest step at 1 in NPT. Drain: automatic (this unit) suits unattended installations, while manual and differential-pressure drains are available where you prefer controlled or pressure-differential dumping. Filter grade: 40 um is standard and suits general air prep; choose the 5 um W option where downstream equipment needs finer protection. Gauge: an embedded square gauge is the standard arrangement and an external round gauge is optional, in MPa, psi or bar scales; this unit carries the round gauge with a psi scale. Thread: PT is the standard thread, with G (BSPP) and NPT as catalogue options to order - this unit is ordered in NPT. A mounting bracket is included unless code J is specified.

One honest note on sizing: flow for this family is published as curves, not as a single rated number, so we cannot quote a rated flow here. Send us your application details and we will confirm the datasheet figures against your required flow before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR600-25ALC2T AirTAC Filter Regulator NPT 1 in FAQ

AirTAC publishes flow for the GFR family as curves, not as a single rated figure, so we do not quote a rated flow, Cv or SCFM number here. Tell us your application and required flow, and we will confirm the datasheet figures for this 600-size, 1 in unit against your demand on request.

The A in the code means the drain bowl empties collected condensate automatically, which suits installations that run unattended. The family is also available with a manual drain (code M) or the differential-pressure drain (no code letter) if you prefer to dump condensate on demand. Drain choice affects the regulator's adjustment range, so confirm the exact figures for the configuration you want with us before ordering.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR600-25ALC2T AirTAC Filter Regulator NPT 1 in

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR60025ALC2T and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.