verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR60025ALC1T AirTAC Filter Regulator NPT1 Low-Pressure

The AirTAC GFR60025ALC1T AirTAC Filter Regulator NPT1 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1" ports, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadNPT
$118.10 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR60025ALC1T AirTAC Filter Regulator NPT1 Low-Pressure

The AirTAC GFR60025ALC1T is a size-600 GFR filter regulator: filtration and pressure regulation combined in a single body. It removes water and particulate from compressed air at a 40 um grade, then regulates downstream pressure, with an automatic drain discharging collected condensate from the bowl without manual attention. This configuration is fitted with 1 in NPT ports, the low-pressure regulator type, a round pressure gauge reading in MPa, and an aluminium alloy bowl. Maximum working (inlet) pressure is 1.0 MPa (145 psi), and the operating temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GFR series is available in sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, and can be ordered with manual, automatic or differential-pressure draining, a 5 um (W) filter grade instead of the 40 um standard, square or round gauges with MPa, psi or bar scales, a reverse/check valve, and G (BSPP) or NPT threads in place of the PT standard. Flow is published as curves rather than a single rated figure, so ask us to confirm flow and datasheet figures for your application before ordering.

GFR60025ALC1T AirTAC Filter Regulator NPT1 Low-Pressure Technical Specifications

ModelGFR60025ALC1T AirTAC Filter Regulator NPT1 Low-Pressure
SeriesGFR600 filter regulator
Port sizePT1" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialAluminium alloy
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR60025ALC1T AirTAC Filter Regulator NPT1 Low-Pressure

GFR600G-series filter regulator, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · PT1" · 40 µm
One size downGFR400
Add lubricationGFC600-25 (two-unit set)

Where the GFR60025ALC1T AirTAC Filter Regulator NPT1 Low-Pressure Is Used

factory

Plant air drop for a packaging hall

Installed at the head of a large packaging-hall air drop, this unit cleans the shop supply of water and scale and holds a steady regulated pressure to the hall's distribution legs, while the automatic drain keeps the aluminium bowl clear of condensate on a line nobody visits daily.

precision_manufacturing

Air preparation for CNC machine tool circuits

Mounted at the machine inlet on a CNC machining centre, it filters incoming compressed air before it reaches tool-clamp and actuator circuits and regulates the supply to the machine's own pressure requirement, with the round MPa gauge giving the setter a direct reading at the panel.

conveyor_belt

Supply point for conveyor actuator runs

Fitted where a conveyor line branches off the main header, it removes moisture and particulate before the diverters and stopper cylinders and regulates their supply pressure, the 1 in NPT ports matching the branch line and the automatic drain suiting an unmanned section of the plant.

Is the GFR60025ALC1T AirTAC Filter Regulator NPT1 Low-Pressure the Right Unit?

Start with the port step: size 600 with 1 in ports is the largest GFR frame, so match it against the air demand of the circuit - if your consumption sits below what a 1 in line carries, a smaller 200/300/400 size may be the more economical choice. Choose the drain to suit access: automatic (this unit) for installations where nobody passes by to drain, manual for supervised points, or the differential-pressure default. Filter grade is 40 um as standard; specify 5 um (code W) only where finer particulate control is genuinely needed. Gauge options are the embedded square gauge or an external round gauge (fitted here) with MPa, psi or bar scales. Thread is PT as the AirTAC standard, with G (BSPP) and NPT as order options - this unit carries NPT. A mounting bracket is included; the J suffix removes it.

Two honest routing notes: flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering. This is the low-pressure type (code L); its exact regulation range is not published in the material we hold, so confirm the regulated band with us before ordering if your circuit runs at reduced pressure.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR60025ALC1T AirTAC Filter Regulator NPT1 Low-Pressure FAQ

AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a rated flow, Cv or SCFM number for this unit. Tell us your operating conditions and required consumption and we will confirm the flow from the datasheet curves for your application before you order.

The L in the code makes this the low-pressure regulator type, intended for circuits regulated below the standard unit's band; its exact regulation range is not published in our material, so confirm it with us before ordering. The A gives an automatic drain, which discharges condensate from the bowl without manual intervention - the alternative codes are M (manual) and blank (differential-pressure). The C1 adds a round gauge reading in MPa; psi and bar scales are available.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR60025ALC1T AirTAC Filter Regulator NPT1 Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR60025ALC1T and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.