verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR60025ALC2G AirTAC Filter Regulator G1 Low-Pressure

The AirTAC GFR60025ALC2G AirTAC Filter Regulator G1 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1" ports, a automatic drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainAutomatic drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadG (BSPP)
$117.94 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR60025ALC2G AirTAC Filter Regulator G1 Low-Pressure

The GFR60025ALC2G is an AirTAC GFR-series filter regulator: water and particulate filtration plus pressure regulation combined in a single body. This size 600 unit is built around a G1 (1 inch) port with G thread, and its configuration is fully decodable from the code: A = automatic drain, so condensate is expelled from the aluminium alloy bowl without manual attention; L = low-pressure regulator type, intended where the working pressure sits below the standard regulator range; C2 = an external round gauge fitted with a psi scale; and the trailing G confirms the G (BSPP) thread option. Filtration is the 40 um standard grade, and the maximum inlet pressure is 1.0 MPa (145 psi) with an operating temperature of -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600, with port sizes stepping from 1/8 in up to 1 in, a choice of automatic, manual or differential-pressure drains, 40 um or 5 um (W) filtration, gauge or no-gauge builds with MPa, psi or bar scales, and PT, G or NPT threads. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application before ordering.

GFR60025ALC2G AirTAC Filter Regulator G1 Low-Pressure Technical Specifications

ModelGFR60025ALC2G AirTAC Filter Regulator G1 Low-Pressure
SeriesGFR600 filter regulator
Port sizePT1" (G (BSPP) thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialAluminium alloy
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR60025ALC2G AirTAC Filter Regulator G1 Low-Pressure

GFR600G-series filter regulator, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
GG (BSPP) thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · PT1" · 40 µm
One size downGFR400
Add lubricationGFC600-25 (two-unit set)

Where the GFR60025ALC2G AirTAC Filter Regulator G1 Low-Pressure Is Used

factory

Large plant air ring main take-off

Where a big production hall feeds a 1 in distribution leg off the main ring, this G1 filter regulator cleans the supply of water and pipe scale and holds the downstream pressure for the whole drop, with the automatic drain keeping the aluminium bowl clear of condensate through long shifts.

conveyor_belt

Heavy conveyor and gate-actuation supply

Conveyor diverters, gate cylinders and stopper units on a packaging or bottling line often run off a single large-bore feed. This unit filters that feed to 40 um and regulates it at low pressure for the actuators, with the round psi gauge giving operators a visible setpoint at the panel.

local_shipping

Truck and trailer shop air station

A commercial-vehicle service bay running impact tools, tyre cages and test rigs from a workshop compressor benefits from one filtered, regulated drop. The 1 in port serves high-draw bays, the automatic drain copes with the moisture a big compressor generates, and the psi gauge lets technicians verify supply pressure before brake or tyre work.

Is the GFR60025ALC2G AirTAC Filter Regulator G1 Low-Pressure the Right Unit?

Start with the size and port: this is the largest step in the range, size 600 with a G1 (1 in) port, chosen when the air demand at the point of use calls for the top of the GFR flow envelope. Because flow is published as curves rather than one rated number, send us your demand and we will confirm the fit against the datasheet before you order. The remaining choices are all real, decodable options: drain type (this unit is automatic; manual and differential-pressure are the alternatives), filter grade (40 um standard here, 5 um with code W where finer filtration is needed), gauge presence and scale (this build carries an external round gauge reading psi; embedded square gauges and MPa or bar scales are the other routes), and thread (G here, with PT as the standard and NPT orderable). A mounting bracket is included with this unit. Note that this is the L low-pressure regulator type; its exact adjustment range is not published in the catalogue, so confirm it with us for your setpoint.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR60025ALC2G AirTAC Filter Regulator G1 Low-Pressure FAQ

AirTAC publishes GFR-series flow as curves, not as a single rated figure, so we do not quote a rated flow, Cv or SCFM number for this unit. Tell us your line pressure and air demand and we will confirm the sizing against the datasheet on request before you order.

The A in the code sets the automatic drain: condensate collected in the bowl is expelled without anyone opening it, which suits unattended or high-moisture installations. The GFR family also offers a manual drain (code M) for periodic attention and a differential-pressure drain (blank code) as the standard; all three are orderable choices on the same size 600 body.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR60025ALC2G AirTAC Filter Regulator G1 Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR60025ALC2G and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.