verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR60025F3WTK AirTAC Filter Regulator 1 in NPT

The AirTAC GFR60025F3WTK AirTAC Filter Regulator 1 in NPT is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadNPT
$119.34 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR60025F3WTK AirTAC Filter Regulator 1 in NPT

The AirTAC GFR60025F3WTK is a size 600 filter regulator that removes water and particulate from compressed air and holds downstream pressure in one body. This configuration carries a 1 in NPT port, a fine 5 um filter element (code W), a differential-pressure drain that bleeds collected condensate automatically as pressure drop builds, and an aluminium alloy bowl, which is the standard bowl material at size 600. A square pressure gauge scaled in bar is fitted, a reverse/check valve (code K) holds the downstream setting if upstream supply is interrupted, and a mounting bracket is included.

This is a genuine AirTAC part. The GFR family spans sizes 200 to 600, with port sizes from 1/8 in to 1 in, a choice of 40 um standard or 5 um fine filtration, differential-pressure, automatic or manual drains, gauge scale options, and PT, G or NPT threads. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and datasheet figures for your application.

GFR60025F3WTK AirTAC Filter Regulator 1 in NPT Technical Specifications

ModelGFR60025F3WTK AirTAC Filter Regulator 1 in NPT
SeriesGFR600 filter regulator
Port sizePT1" (NPT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — square, bar scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR60025F3WTK AirTAC Filter Regulator 1 in NPT

GFR600G-series filter regulator, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
3Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · PT1" · 5 µm
One size downGFR400
Add lubricationGFC600-25 (two-unit set)

Where the GFR60025F3WTK AirTAC Filter Regulator 1 in NPT Is Used

factory

Plant air main regulation

Drops a 1 in compressed-air main feeding a production hall to its working pressure, with 5 um filtration protecting every downstream drop and the check valve holding the setting through supply dips.

conveyor_belt

Packaging and conveyor lines

Feeds cylinder- and actuator-driven conveyor and case-packing equipment with clean, regulated air; the differential-pressure drain keeps condensate off the line without daily manual attention.

settings_input_component

Automated machine supply

Serves as the single conditioning point on an automated machine's air inlet, filtering to 5 um ahead of precision valves and holding a stable bar-set pressure read on the fitted square gauge.

Is the GFR60025F3WTK AirTAC Filter Regulator 1 in NPT the Right Unit?

Start with the port step: size 600 with a 1 in NPT port sits at the top of the GFR range, so step down to 200/300/400 if your line runs smaller ports and lower air demand. Choose the drain next: differential-pressure (this unit) suits steady duty, automatic drain suits unattended installations, and manual drain suits periodically attended stations. Pick the filter grade to match the downstream equipment: 40 um standard for general protection, 5 um (this unit, code W) for finer components such as precision valves and instruments. Gauge scale is selectable (MPa, psi or bar; this unit is square, bar), and thread is PT as standard with G and NPT as order options - this unit is NPT. A bracket is included; a reverse/check valve can be specified (fitted here, code K).

One honest note on sizing: flow is published as curves, not a single rated number, so send us your application details and we will confirm the right size against the curves before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR60025F3WTK AirTAC Filter Regulator 1 in NPT FAQ

AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow figures from the datasheet so you can size the unit correctly before ordering.

The W in the code specifies the fine 5 um filter element instead of the 40 um standard, which suits downstream precision valves and instruments. The K specifies a reverse/check valve, which holds the regulated downstream pressure if the upstream supply is interrupted. Both are standard catalogue options on the GFR family.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR60025F3WTK AirTAC Filter Regulator 1 in NPT

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR60025F3WTK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.