verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR60025LF2T AirTAC Filter Regulator 1 in NPT Low-Pressure

The AirTAC GFR60025LF2T AirTAC Filter Regulator 1 in NPT Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadNPT
$107.62 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR60025LF2T AirTAC Filter Regulator 1 in NPT Low-Pressure

The AirTAC GFR60025LF2T is a size 600 filter regulator: it removes water and particulate from compressed air and sets downstream pressure in a single body. This configuration is the low-pressure type with a 1 in NPT port, a 40 um standard filter element, and a differential-pressure drain in the aluminium alloy bowl, which opens automatically as the bowl fills so the unit keeps working without manual attention. The embedded square gauge is fitted and reads in psi, so operators can check and adjust setpoints at a glance, and the mounting bracket is included for panel or wall fixing.

This is a genuine AirTAC part from the GFR range, which spans sizes 200, 300, 400 and 600 with port options from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drain, a 5 um (code W) element option, alternative gauge scales, and PT or G thread variants. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Rated flow is published as curves rather than a single figure, so ask us to confirm the datasheet and sizing for your application.

GFR60025LF2T AirTAC Filter Regulator 1 in NPT Low-Pressure Technical Specifications

ModelGFR60025LF2T AirTAC Filter Regulator 1 in NPT Low-Pressure
SeriesGFR600 filter regulator
Port sizePT1" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — square, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR60025LF2T AirTAC Filter Regulator 1 in NPT Low-Pressure

GFR600G-series filter regulator, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
FGauge shape: Square. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · PT1" · 40 µm
One size downGFR400
Add lubricationGFC600-25 (two-unit set)

Where the GFR60025LF2T AirTAC Filter Regulator 1 in NPT Low-Pressure Is Used

factory

Low-pressure palletizer and case-erector supply

Feeds filtered, regulated air to the large-bore cylinders and air cushions on end-of-line palletizing equipment that runs at reduced setpoints, with the psi gauge letting maintenance set the line pressure directly.

conveyor_belt

Conveyor air-knife drying station

Supplies cleaned, pressure-limited air to air-knife nozzles over a bottling or canning conveyor, where the 1 in port serves the high-volume low-pressure circuit and the differential-pressure drain keeps condensate moving out during continuous shifts.

valve

Large actuator control on a wastewater gate valve

Regulates supply to the big double-acting actuator on a sluice or penstock valve, where the low-pressure type suits the reduced setpoint and the aluminium bowl and included bracket stand up to plant-room mounting.

Is the GFR60025LF2T AirTAC Filter Regulator 1 in NPT Low-Pressure the Right Unit?

Start with the port and size: this unit steps up to 1 in NPT on the size 600 body, the largest in the GFR range, so it suits lines with substantial air demand where smaller ports would restrict supply. Because flow is published as curves rather than a single rating, send us your demand figures and we will confirm the right size before you order. Choose the drain to match the installation: the differential-pressure drain fitted here is the default and suits continuous operation; automatic drain (code A) suits unattended duty, and manual drain (code M) suits intermittent use. The 40 um element fitted here is the standard grade; specify code W for the 5 um element where finer filtration is needed. The square gauge reads in psi; MPa and bar scales are also available. Thread is NPT here; PT is the catalogue standard and G (BSPP) is an order option. A bracket is included; on some GFR sizes code J deletes it.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR60025LF2T AirTAC Filter Regulator 1 in NPT Low-Pressure FAQ

AirTAC publishes flow for the GFR600 series as performance curves rather than a single rated number, so we do not quote a figure here. Send us your line pressure, setpoint and air demand and we will confirm the flow from the datasheet and check the sizing against your application before you order.

The L marks the low-pressure type of regulator, intended for reduced downstream setpoints; the exact adjustment range for this type is not published in the standard tables, so we confirm it on request. The drain is the differential-pressure type (no drain letter in the code): it bleeds condensate out of the aluminium bowl automatically as pressure differential builds, with no manual draining needed during normal running.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR60025LF2T AirTAC Filter Regulator 1 in NPT Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR60025LF2T and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.