verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR60025LJC2TK AirTAC Filter Regulator NPT1 Low-Pressure

The AirTAC GFR60025LJC2TK AirTAC Filter Regulator NPT1 Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadNPT
$117.81 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR60025LJC2TK AirTAC Filter Regulator NPT1 Low-Pressure

The AirTAC GFR60025LJC2TK is a size-600 filter regulator that removes water and particulate from compressed air and regulates downstream pressure in one body. This configuration is the low-pressure type, fitted with an external round gauge scaled in psi, a reverse/check valve to hold the set pressure against backflow, and a differential-pressure drain that bleeds condensate from the aluminium alloy bowl as flow passes through. The 1 in NPT port suits a main air line serving several downstream devices.

This is a genuine AirTAC part. The GFR series is available in sizes 200, 300, 400 and 600 with a choice of thread (PT standard, G or NPT to order), drain type, 40 um or 5 um filtration, gauge style and scale, and bracket options. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.

GFR60025LJC2TK AirTAC Filter Regulator NPT1 Low-Pressure Technical Specifications

ModelGFR60025LJC2TK AirTAC Filter Regulator NPT1 Low-Pressure
SeriesGFR600 filter regulator
Port sizePT1" (NPT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — round, psi scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR60025LJC2TK AirTAC Filter Regulator NPT1 Low-Pressure

GFR600G-series filter regulator, 600 body — sets the port range.
25Port size PT1". This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
TNPT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · PT1" · 40 µm
One size downGFR400
Add lubricationGFC600-25 (two-unit set)

Where the GFR60025LJC2TK AirTAC Filter Regulator NPT1 Low-Pressure Is Used

factory

Low-pressure supply for packaging line air knives

On a packaging line, blow-off air knives and cooling jets run at low setpoints. This low-pressure GFR unit filters the supply and holds a gentle, stable regulated pressure, while the check valve keeps the setting if the main supply dips between machine cycles.

conveyor_belt

Main line regulation for conveyor actuator banks

A conveyor system with pneumatic diverters, stoppers and lifters draws air from a 1 in header. This filter regulator cleans the header supply, regulates it for the whole actuator bank, and the psi gauge lets maintenance read the line setting at a glance.

science

Filtered, regulated air for lab and process equipment

Process and laboratory skids with air-operated valves and sample-handling cylinders need clean air at a low, steady pressure. This unit provides 40 um filtration and low-pressure regulation at the skid inlet, with the check valve preventing backflow into the supply header.

Is the GFR60025LJC2TK AirTAC Filter Regulator NPT1 Low-Pressure the Right Unit?

Size 600 with a 1 in port sits at the top of the GFR range, so start there when the line feeds multiple actuators or high-demand equipment and verify the flow curve against your consumption before ordering. This unit is the low-pressure type (code L): choose it when the working setpoint sits at the low end of the scale, and ask us to confirm the exact adjustment range from the datasheet, since it is not published as a single figure. The differential-pressure drain is the default and suits steady-flow lines; if the line stops often, ask about automatic or manual drain variants. Filtration is the standard 40 um element, fine enough for general actuator and valve supply - specify 5 um (code W) only where finer protection is required. The round gauge here reads in psi; square embedded gauges and MPa or bar scales are alternatives. Thread is NPT on this unit (PT is the AirTAC standard, G is also orderable), and code J means no mounting bracket is included - add one if the unit will not be line-supported. The fitted check valve (code K) holds downstream pressure if the upstream supply drops.

Quick checklist

  • ✓ Body size for your peak flow (PT1" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

GFR60025LJC2TK AirTAC Filter Regulator NPT1 Low-Pressure FAQ

AirTAC publishes flow for the GFR series as performance curves, not as a single rated figure, so we do not quote a number here. Tell us your line pressure, set pressure and air consumption, and we will confirm the sizing from the datasheet curves before you order.

Code L in the model marks the low-pressure regulator type, intended for applications where the working setpoint sits at the low end of the scale; its exact adjustment range is not published as a single figure, so we confirm it from the datasheet on request. Code K means a reverse/check valve is fitted, which holds the downstream pressure if the upstream supply is interrupted.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR60025LJC2TK AirTAC Filter Regulator NPT1 Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR60025LJC2TK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.